DeWalt D55155 Instruction Manual
Hide thumbs Also See for D55155:

Advertisement

InstruCtIon MAnuAl
GuIDE D'utIlIsAtIon
MAnuAl DE InstruCCIonEs
D55151, D55152, D55153, D55155
Contractor's Electric 4 Gallon Hand Carry Air Compressor
Compresseurs d'air portatifs électriques de 4 gallons de classe entrepreneur
Compresor de aire portátil elèctrico de 4 galones para contratistas
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-D
WALT • www.dewalt.com
e
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA
DE GARANTÍA. ADVErtEnCIA: LÉASE ESTE INSTRUCTIVO ANTES
DE USAR EL PRODUCTO.

Advertisement

Table of Contents
loading

Summary of Contents for DeWalt D55155

  • Page 1 DE GARANTÍA. ADVErtEnCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. MAnuAl DE InstruCCIonEs D55151, D55152, D55153, D55155 Contractor’s Electric 4 Gallon Hand Carry Air Compressor Compresseurs d’air portatifs électriques de 4 gallons de classe entrepreneur Compresor de aire portátil elèctrico de 4 galones para contratistas...
  • Page 2 NOT A Air Compressor STEP FIG. 1 A. On/Off Switch B. Air Tank Pressure Gauge C. Regulated Pressure Gauge D. Pressure Regulator E. Quick Connects (if equipped) F. Check Valve G. Safety Valve H. Air Tank Drain Valve I. Power Cord Wrap J.
  • Page 3: Specifications

    Specifications MoDEl D55151 D5515 D5515 D55155 WEIGHt 56 lbs. (5.4 kg) 65 lbs. (9.5 kg) 58 lbs. (8. kg) 61 lbs. (7.7 kg) HEIGHt 16.75" (45.5 mm) 16.0" (406.4 mm) 16.75" (501.7 mm) 1.5" (17.5 mm) WIDtH 18.0" (457. mm) 18.0"...
  • Page 4: Hot Surfaces

    Hot Surfaces IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT PUMP THIS OR ANY D WALT TOOL, CALL US TOLL FREE AT: CYLNDER FIG.  1-800-4-D WAlt (1-800-433-9258) AND HEAD Important Safety Instructions WARNING: Do not operate this unit until you read and understand this instruction manual for safety, operation and maintenance instructions.
  • Page 5 • Unattended operation of • Always remain in attendance this product could result in with the product when it is personal injury or property operating. damage. To reduce the risk DANGER: RISk Of ExPlOSION OR fIRE • Always turn off and unplug of fire, do not allow the unit when not in use.
  • Page 6 • Sprayed materials such as • Work in an area with good paint, paint solvents, paint cross ventilation. Read and remover, insecticides, weed follow the safety instructions WARNING: RISk Of BURSTING killers, may contain harmful provided on the label or safety vapors and poisons.
  • Page 7 Attachments & accessories: • Electrical Grounding: • Make certain that the Failure to provide adequate electrical circuit to which the • Exceeding the pressure • Follow the equipment grounding to this product compressor is connected rating of air tools, spray guns, manufacturers could result in serious injury provides proper electrical...
  • Page 8 • Attempting to operate • Any repairs required on this compressor with damaged or product should be performed missing parts or attempting by a D WALT factory WARNING: RISk Of HOT SURfACES to repair compressor with service center or a D WALT protective shrouds removed authorized service center.
  • Page 9: Features

    FEATurES (Fig. 1) • Equip area of operation with a fire extinguisher. on/off sWItCH • Do not operate machine with Place this switch (A) in the ON position to missing, broken, or unautho- provide automatic power to the pressure rized parts. switch and OFF to remove power at the end of each use.
  • Page 10: Installation

    AIr CoMprEssor puMp tAnk prEssurE GAuGE The pump compresses air into the air tank. Working air is not The tank pressure gauge (B) indi- available until the compressor has raised the air tank pressure cates the reserve air pressure in above that required at the air outlet.
  • Page 11: Lubrication And Oil

    Grounding Instructions . Grasp the hose at the quick connect plug and push the plug into the quick connect body (E). Coupler will snap into place. WARNING: Risk of electrical shock. In the event of a short . Grasp the hose and pull to ensure coupler is seated. circuit, grounding reduces the risk of shock by providing an escape wire for the electric current.
  • Page 12: Extension Cords

    Extension Cords If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be Using extension cords is not recommended. The use of extension necessary to operate it from a 20 amp circuit. It is not necessary to cords will cause voltage to drop resulting in power loss to the motor change the cord set.
  • Page 13: Preparation For Use

    ElECtrICAl CAUTION: Do not operate without oil or with inadequate oil. D WAlT Refer to all safety instructions before using unit. Observe extension is not responsible for compressor failure caused by inadequate oil. cord safety instructions if necessary. Always move the On/Off 7.
  • Page 14: Operating Procedures

    . Open the drain valve (counter-clockwise) fully to permit air to 4. Drain the air tank, see Draining Air tank under Maintenance. escape and prevent air pressure build up in the air tank during Ensure air tank pressure gauge reads 0 PSI (0 kPa). the break-in period.
  • Page 15: Maintenance Chart

    Maintenance Chart WARNING: Risk of bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or procedure Daily Weekly Monthly 1 year or an explosion. Before starting compressor, pull the ring on the safety valve to 200 Hours make sure that the safety valve operates freely. If the valve is stuck Check safety valve...
  • Page 16 notE: All compressed air systems generate condensate that . Remove dipstick (K) and wipe clean. accumulates in any drain point (e.g. tanks, filter, aftercoolers, dryers). 4. Reinsert dipstick fully into oil fill port for a few This condensate contains lubricating oil and/or substances which seconds to allow oil to collect on the dipstick.
  • Page 17: Service Information

    Baltimore, MD 186, call 1-800-4-D WALT (1-800-4-958) or visit frEE WArnInG lABEl rEplACEMEnt: If your warning labels our website www.dewalt.com. become illegible or are missing, call 1-800-4-D WALT for a free CAUTION: The use of any other accessory not recommended for replacement.
  • Page 18 GLoSSArY CfM: Cubic feet per minute. sCfM: Standard cubic feet per minute; a unit of measure of air delivery. psI: Pounds per square inch; a unit of measure of pressure. kpa (kilopascal): Metric pressure measurement. 1 kilopascal equal 1000 pascals. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
  • Page 19: Troubleshooting Guide

    Troubleshooting Guide This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified D WALT technician or your dealer. problem Code Excessive air tank pressure-safety valve pops off ..............1,...
  • Page 20 CoDE possIBlE CAusE possIBlE solutIon Tube fittings are not tight enough Tighten fittings where air can be heard escaping. Check fittings with soapy water solution. Do Not Overtighten. Defective air tank Air tank must be replaced. Do not repair the leak. WARNING: Risk of bursting. Do not drill into, weld or otherwise modify air tank or it will weaken. The air tank can rupture or explode.
  • Page 21 CoDE possIBlE CAusE possIBlE solutIon Regulator is damaged Replace. Unit operating in damp or humid conditions Move unit to a dry well ventilated area Restricted air intake filter Clean or replace air intake filter Pump oil is low Add D WALT synthetic compressor oil to pump.
  • Page 22 CoDE possIBlE CAusE possIBlE solutIon Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.

This manual is also suitable for:

D55152D55151D55153

Table of Contents