Miele PT 8407 EL Installations Plan page 12

Hide thumbs Also See for PT 8407 EL:

Advertisement

Equipotential
Connection with male thread
bonding
with washers and nut.
Accessories not included (except with offshore version).
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Vented
Max. nominal air flow in vented mode
Max. permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Alternative connection: Ducted air intake (from outside
building)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm (35 ½") long and secured using two screws.
Fittings
Without base
(supplied)
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
On concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
Machine depth
Unit height
Casing width
Casing depth
Minimum width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Min. wall gap (to rear edge of lid)
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and program
selected)
Noise level
Sound pressure level
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
Installation should only be carried out by authorized fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved!
Installation plan: PT 8407 EL (Electric)
Date: 01.2015
Unobstructed air intake into room recommended (corre-
sponding to 3 times the vent cross-section of machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
3/8" x 1 3/8"
10 × 35 mm
10 M
470cfm
800 m³/h
0.04 psi
300 Pa
5 15/16"
150 mm
5 15/16"
150 mm
176°F
80°C
83 in²
531 cm²
6 5/16"
161 mm
6 5/16"
160 mm
¼ x 1 9/16"
6 x 40 mm
3/8 x 2"
10 x 50 mm
¼ x 1 9/16"
6 × 40 mm
3/8 x 2"
10 × 50 mm
35 11/16"
906 mm
45 13/16"
1164 mm
55 1/8"
1400 mm
35 7/16"
900 mm
41 11/16"
1059 mm
36 ¼"
920 mm
63"
1600 mm
19 11/16"
500 mm
422 lb
191 kg
2170 N
2170 N
2220 BTU/hr
0.65kW
72.8 dB (A)
72.8 dB (A)
60 dB (A)
60 dB (A)
Page: 12