Download Print this page

Panasonic LC2H preset Specifications page 3

Timers/time switches/counters/hour meters
Hide thumbs Also See for LC2H preset:

Advertisement

2) Installation frame type
1 Standard type
No. digits
Counting speed
2 kHz/30 Hz switchable
8 digits
Note) Please ask us about types without front resetting.
2 Backlight type
No. digits
Counting speed
8 digits
2 kHz/30 Hz switchable
2. PC board mounting type
No. digits
Counting speed
8 digits
Specifications
1. Panel mounting type
Item
No. digits
External power supply
Max. counting speed
Min. input signal width
(ON: OFF = 1:1)
Input method (signal)
Count
input
Input impedance
Residual voltage
Min. input signal width
Input method (signal)
Reset
input
Input impedance
Residual voltage
Display method
Breakdown voltage (initial)
Insulation resistance (initial)
Backlight power
Protective construction (Note 3)
Accessories (Note 3)
Battery life
Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed.
Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode.
2. Operation is at 25 Hz when using 24 V AC.
3. Only for installation frame type.
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Front reset
Yes
30 Hz
Front reset
Yes
Front reset
2 kHz
No
30 Hz
Standard type
Type
Non-voltage input
2 kHz/30 Hz (Switchable by switch)
0.25 ms/16.7 ms (Switchable by switch)
Non-voltage input using
contacts or open collector
connection
When shorted:
Max. 10 kΩ
When open:
Max. 750 kΩ
Max. 0.5 V
Non-voltage input using
contacts or open collector
connection
When shorted:
Max. 10 kΩ
When open:
Max. 750 kΩ
Max 0.5 V
7-segment LCD
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
IEC Standard IP66 (only panel front: when using rubber gasket)
7 years (at 25°C 77°F) Note 1
Input method
Non-voltage input type
Voltage input type (4.5 to 30 V DC)
Free voltage input type (24 to 240 V AC/DC)
Input method
Voltage input type (4.5 to 30 V DC)
Input method
Non-voltage input type
Backlight type
Voltage input
8 digits
Not required (built-in battery)
High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC
Approx. 4.7 kΩ
200 ms
High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC
Appox. 4.7 kΩ
7-segment LCD
With green/red backlight
24 V DC (±10%)
Rubber gasket, mounting bracket
LC2H
Part No.
LC2H-F-2KK
LC2H-F-DL-2KK
LC2H-F-FV-30
Part No.
LC2H-F-DL-2KK-B
Part No.
LC2H-C-2K-N
LC2H-C-30-N
Standard type
Free voltage type
30 Hz (Note 2)
16.7 ms
High level:
24 to 240 V AC/DC
Low level:
0 to 2.4 V AC/DC
Non-voltage input using
contacts or open collector
connection
When shorted:
Max. 10 kΩ
When open:
Max. 750 kΩ
Max. 0.5 V
7-segment LCD
Between charged and
uncharged parts: 2,000 V
AC for 1 minute.
6 years (at 25°C 77°F)

Advertisement

loading