Power Supply For Terminating Resistor; Scsi Termination Circuit; Requirements For Terminating Resistor Power Supply - Fujitsu MCE3064SS Product Manual

Table of Contents

Advertisement

(2)
Termination circuit
The termination circuit is a resistor termination as shown in Figure 7.4. The termination circuits
are installed in SCSI devices which are connected at both ends of the interface cable.
7.3.2

Power supply for terminating resistor

The TERMPWR signal on the interface connector is used to supply power to the terminating
resistor circuit connected to both ends of the cable. In a system configuration where the
terminating resistor is installed outside the SCSI device or if there is a possibility of the power to
the SCSI device with the terminating resistor being cut off, power for the terminating resistor
must be supplied to the TERMPWR line from an SCSI device on the bus. The SCSI device
always working as an INIT (example: host adapter) should supply that power. Power must be
supplied to the TERMPWR line through a diode or other element to prevent reverse current.
Table 7.2 lists the requirements for terminating the resistor power supply (V
Table 7.2
Output voltage
Current capacity
Sink current
Figure 7.4

SCSI termination circuit

Requirements for terminating resistor power supply

Item
C156-E097-01EN
Single-ended type
4.25 to 5.25 VDC
900 mA min.
1.0 mA max.
)
term
7 - 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mcf3064ss

Table of Contents