Yamaha YK250XGC Installation Manual page 60

Table of Contents

Advertisement

Check that the X-axis and Y-axis
q
stop firmly.
Whether or not the X-axis stops at a position
before the stopper limited by the maximum
soft limit must be checked from the outside
of the safety enclosure.
2
The X-axis may not stop at a position before the
stopper due to the stopper part accuracy or
position. If this happens, decrease the value while
referring to the Table
previously.
Installing the additional stoppers in both the plus and minus directions
Install the additional stoppers in both the plus and minus directions while referring to the Fig. below.
2-12
"■
Soft limits" described
Installing the additional stoppers in both the plus and minus directions
Use the bolt and seal washer
to protect the tapped hole.
Y-axis minus direction additional stopper
(Move the standard stopper to this position
and secure it.)
*1
Y-axis plus direction additional stopper
Use the bolt and washer to
protect the tapped hole.
X-axis plus direction additional stopper
X-axis minus direction additional stopper
*2
*1 Bolt tightening torque: 16Nm (163kgfcm)
*2 Bolt tightening torque: 42Nm (428kgfcm)
*2
*1
*2
*2
23214-HM-00