Operating Instructions ® Busch-Wächter Pos: 4 /#Neustruktur#/Online-Dokumentation (+KNX)/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1 Safety ..................................3 Intended use ................................3 Environment ................................3 Setup and function ..............................4 Features of function and equipment ......................4 Detection ranges .............................
Operating Instructions ® Busch-Wächter Safety Pos: 6 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1 Safety Pos: 7 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1 Warning Electric voltage! Risk of death and fire due to electrical voltage of 230 V.
Pos: 13 /#Neustruktur#/Online-Dokumentation (+KNX)/Aufbau und Funktion/Waechter/Funktionen - 6854 70 MasterLINE @ 28\mod_1347373855300_15.docx @ 232808 @ 2 @ 1 The Busch-Watchdog 70 MasterLINE is a movement detector with a reduced detection range and is suitable for use in small terraced houses.
Operating Instructions ® Busch-Wächter Installation and electrical connection Pos: 27 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 3333333 @ 1 Mounting Pos: 28 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ 1322133 @ 1 Warning Electric voltage! Risk of death and fire due to electrical voltage of 230 V.
Operating Instructions ® Busch-Wächter Installation and electrical connection 6.2.2 Preparing the installation To prepare the installation of the device, perform the following steps: Fig. 3: Preparing the installation 1. Remove the locking screw (1) (if installed). 2. Press in the clamps (2 ... 5) on the sides of the housing with a suitable tool. 3.
Operating Instructions ® Busch-Wächter Installation and electrical connection 6.2.3 Mounting steps Fig. 5: Fixing to the wall Connecting terminals Connection Function Neutral conductor → switched phase? Phase (230 V AC, 50 / 60 Hz Grounding conductor connection 1. Mount the device on the wall. ∅6,5 mm - 8,5 mm Do not use countersunk head screws for mounting to the wall.
Page 10
Operating Instructions ® Busch-Wächter Installation and electrical connection For cable cross sections larger than 1.5 mm² use only cable entry (B) or (C). 3. To protect the device against unauthorized opening, the enclosed screw can be used on the bottom of the device.
Operating Instructions ® Busch-Wächter Installation and electrical connection 6.3.3 Standard connection with triple-step switch Fig. 8: Universal relay insert with triple-step switch The connection is made with a triple-step switch such as 2713 U, 2710 U Step switch function: 1. Continuous light 2.
Operating Instructions ® Busch-Wächter Operation Pos: 40 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Nebenstellenbetrieb @ 18\mod_1308568178899_15.docx @ 107029 @ 2222222 @ 1 Auxiliary post operation Pos: 41 /#Neustruktur#/Online-Dokumentation (+KNX)/Nebenstellenbetreib/Waechter/Nebenstellenbetrieb - 6854 -- 70 MasterLINE @ 29\mod_1347536933190_15.docx @ 233375 @ 2222 @ 1 8.3.1 Operation with extension unit push-button Aside from the movement detector being triggered by the infrared radiation in the detection range, manual...
Page 16
PO box contents of this document without prior notice. 58505 Lüdenscheid The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no Freisenbergstraße 2 responsibility for possible errors or 58513 Lüdenscheid incompleteness in this document.