ABB Adam DYN-Info M12-5 Product Manual

ABB Adam DYN-Info M12-5 Product Manual

Coded non-contact safety sensor
Hide thumbs Also See for Adam DYN-Info M12-5:

Advertisement

Quick Links

SAFETY PRODUCTS
Eden DYN
Coded non-contact safety sensor
Product Manual
2TLC172271M0201
Rev.H
PRODUCT MANUAL
new.abb.com/low-voltage/products/safety-products

Advertisement

Table of Contents
loading

Summary of Contents for ABB Adam DYN-Info M12-5

  • Page 1 — SAFETY PRODUCTS Eden DYN Coded non-contact safety sensor Product Manual 2TLC172271M0201 Rev.H PRODUCT MANUAL new.abb.com/low-voltage/products/safety-products...
  • Page 2 Suitability for use ABB shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. Third party certificates for the products are available at https://new.abb.com/low-voltage/products/safety-products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
  • Page 3: Table Of Contents

    Models of Adam and Eva ........................8 Adam DYN ..............................8 Eva ................................9 Electrical connections ..................... 10 Adam DYN-Info M12-5 ........................... 10 Adam DYN-Reset M12-5 ........................11 Adam DYN-Status M12-5 ........................11 Connection of cable C5 to M12 C01 and M12 C02 connectors ............12 Parallel connection with Eden ......................
  • Page 4 How to program a new Adam without code, to accept a new Eva ........... 22 How to erase existing codes from Adam .................... 22 Replacing Eva (Not needed for General to General switch) ............... 22 Testing the safety functions ........................ 23 Info output (pin-5) –...
  • Page 5: Introduction

    This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB safety products. • Knowledge of machine safety. Special notes Pay attention to special notes in the document:...
  • Page 6: Safety

    2 Safety Safety precautions The safety precautions must be followed during installation, operation, maintenance and troubleshooting. It is the responsibility of the user to ensure the correct overall functionality of its systems and machines. Warning! Carefully read through the entire product manual before using the device. Warning! The devices shall be installed by authorized personnel following the Safety regulations, standards and the Machinery directive.
  • Page 7: Product Description

    3 Product description Eden DYN sensor consists of two separate devices, Adam and Eva, intended for use as interlocking device for gates, hatches etc. Eva can be general coded or unique coded. Eden DYN meets the coding requirements according to EN ISO 14119:2013 regarding manipulation protection.
  • Page 8: Models Of Adam And Eva

    Adam DYN Adam DYN exists in different models: Adam DYN-Info, Adam C DYN-Info, Adam DYN-Reset and Adam DYN-Status. Adam DYN-Info M12-5 DYNlink model with information output. Adam C DYN-Info M12-5 DYNlink model with information output and coated electronics to provide increased resistance in demanding environments.
  • Page 9: Eva

    Eva exists in different models: Eva General code, Eva C General code, Eva Unique code and Eva C Unique code. It is possible to mix different models of Eva in the same safety circuit. Eva General code The Eva units with general code have all the same code and fulfills the requirement for a low-level coded interlocking device according to EN ISO 14119:2013.
  • Page 10: Electrical Connections

    4 Electrical connections Note! Use a suitably insulated low-voltage supply system type SELV or PELV. Adam DYN-Info M12-5 M12 5-pole male M12 5-pole female from cable side from cable side M12-connector: (5-pole male) 1 ) Brown: +24 VDC 2 ) White:...
  • Page 11: Adam Dyn-Reset M12-5

    2) White: DYNlink signal in 3) Blue: 0 VDC 4) Black: DYNlink signal out 5) Grey: Info/StatusBus Note! The use of shielded cable is recommended for enhanced electromagnetic immunity. Caution! All cable colors according to ABB standard cables. 2TLC172271M0201 Rev.H...
  • Page 12: Connection Of Cable C5 To M12 C01 And M12 C02 Connectors

    Connection of cable C5 to M12 C01 and M12 C02 connectors Female 5-pin connector (M12 C01): Brown 2) White 3) Blue Male 5-pin connector (M12 C02): 4) Black 5) Grey Parallel connection with Eden Eden can be connected in parallel with other DYNlink devices in a safety circuit, to create a muting/bypass function.
  • Page 13: Connection Of Reset Button To Adam Dyn-Reset

    The maximum current consumption for the indication lamp is 30 mA. Smile 12RF is a reset button with indication lamp from ABB intended to be used together with Adam DYN-Reset. The minimum current consumption needed through the lamp is 10 mA. If no lamp is used, a 4.7 kOhm resistor can be used instead.
  • Page 14: Serial Connection

    Serial connection Serial connection of three Adam DYN-Reset with Smile 12 RF to Pluto or Vital via M12-3A. 2TLC172271M0201 Rev.H...
  • Page 15: Connection Examples

    5 Connection examples Adam DYN-Info connected to Vital 1 B) Adam DYN-Info connected to Vital 1 with manual A) Adam DYN-Info connected to Vital 1 with reset. automatic reset. 2TLC172271M0201 Rev.H...
  • Page 16: Several Adam Dyn-Info Connected In Series To Vital 1

    Several Adam DYN-Info connected in series to Vital 1 A) Three Adam DYN-Info connected to Vital 1 with automatic reset. Several Adam DYN-Status connected in series to Pluto A) Two Adam DYN-Status connected to a Pluto Safety PLC. Left unit connected to use StatusBus, right unit connected to use Info. 2TLC172271M0201 Rev.H...
  • Page 17: Several Adam Dyn-Status Connected In Series To Pluto Via M12-3S

    Several Adam DYN-Status connected in series to Pluto via M12-3S A) Three Adam DYN-Status connected to a Pluto Safety PLC via M12-3S to use StatusBus. Y-connectors M12-3A M12-3B M12-3S 2TLC172271M0201 Rev.H...
  • Page 18: Installation

    6 Installation Installation precautions Warning! All safety functions shall be tested before starting up the system. • Note that the detection distance can be affected when Eden is mounted close to metal. • The Eden can be mounted on metal but must not be surrounded. •...
  • Page 19: Detection Distance

    Detection distance Eva can be turned in several different ways relative to Adam, see details in the figure below. The green fields in the picture show the detection range of Adam relative to Eva. The Eva is detected when the two coils (see red-marked areas, image below) in Eva are in contact with the green field. The figures above shows maximum detection distances.
  • Page 20: Mounting

    Mounting Depending on the cable connector used for the connection to Eden, one or two distance plates might be required for correct mounting to avoid damaging Adam. It is recommended to use the distance plates DA 1B, supplied with the Adam, see figure below. Also, the mounting spacers DA 2B supplied must be used to physically protect Eden from damage.
  • Page 21: Mounting Procedure

    Mounting procedure Fasten each sensor with two M4-screws. Safety screw SM4x20 (2TLA020053R4200) is recommended. The DA 2B mounting spacers must be used to physically protect Eden from damage. 2. Use max tightening torque 1.0 Nm on screws. 3. Lock screw with Loctite or similar if necessary, to prevent easy dismounting (refer to risk assessment).
  • Page 22: Teaching The Code

    Teaching the code Adam is without code in its factory setting mode and need to be programmed with the code from an Eva (General or Unique coded). The code of the first Eva detected by the Adam is automatically programmed as soon as Eva is within the detection distance. If Adam is programmed to accept an Eva with a general code, it will accept all Eva units with a general code.
  • Page 23: Testing The Safety Functions

    Testing the safety functions Make sure the safety unit and safety module (Vital/Pluto/URAX) is working properly by following these steps: Interrupt Eden output by moving Eva away from Adam. The LED will light red when Eva is out of range of Adam. 2.
  • Page 24: Info Output (Pin-5) - Information/Statusbus

    1–30. This can be done manually or automatically done using ‘Pluto Manager StatusBus Teach addresses’ functionality. For more information about the StatusBus, refer to the user manual for Pluto at: new.abb.com/low-voltage/products/safety-products StatusBus message from slave contains 3 information bits. •...
  • Page 25: Led Indication

    7 LED indication The non-safe status LED on Adam shows the status of the Eden sensor and the output status as follows: LED on Adam Description Safety circuit Green Valid Eva within range Closed Flashing green Valid Eva within range, waiting for reset Open Flashing red/green Valid Eva within range, no valid in signal...
  • Page 26: Maintenance

    Warning! In case of breakdown or damage to the product, contact ABB. Do not try to repair the product. It might accidentally cause permanent damage, impairing the safety of the device and in turn lead to serious injury to personnel.
  • Page 27: Compatibility With Analog Models Of Eden

    9 Compatibility with analog models of Eden Eden DYN is designed to be compatible with analog models of Eden, still there are differences. The compatibility of Eden DYN and analog Eden are limited to: Eden DYN uses a processor based digital technique and the analog Eden uses analog technique. This difference in technology creates some differences in the processing of the DYNlink signal.
  • Page 28: Model Overview

    10 Model overview Model Product ID Description Adam DYN-Info M12-5 2TLA020051R5100 Pin 5: Information Adam C DYN-Info M12-5 2TLA020051R5101 Pin 5: Information Adam DYN-Reset M12-5 2TLA020051R5300 Pin 5: Reset/Indication Adam DYN-Status M12-5 2TLA020051R5200 Pin 5: Information/StatusBus Eva General code 2TLA020046R0800...
  • Page 29: Technical Data

    11 Technical data Manufacturer Address ABB Electrification Sweden AB SE-721 61 Västerås Sweden Power supply Rated operating voltage +24 VDC +15 % -40 % Use SELV/PELV Current consumption 30 mA at 24 VDC 35 mA at 18 VDC (45 mA at 12 VDC)
  • Page 30 Information for use in USA / Canada Enclosure Type 1, 4, 4x Intended use Applications according to NFPA 79 Power source Only suitable for use in a limited voltage / current circuitry. The limited voltage / current source must comply with one of the following: a) An isolating device such that the maximum open circuit voltage potential available to the circuit is not more than +24 VDC and...
  • Page 31: Guideline For Chemical Resistance

    Guideline for chemical resistance Chemicals Eden DYN Hydrocarbons aliphatic Good aromatic Good halogenated - fully Poor/Fair - partly Poor Alcohols Good Phenols Poor Ketones Fair/ Good Amines Not tested Esters Fair/ Good Ethers Good Acids inorganic Good organic Fair oxidizing Poor Alkalis Poor...
  • Page 32: Eden Dimensions

    Eden dimensions Adam M12, contact seen from outside. All dimensions in millimeters. CAD model For CAD models please visit new.abb.com/low-voltage/products/safety-products 2TLC172271M0201 Rev.H...
  • Page 33: Declaration Of Conformity

    12 Declaration of conformity 2TLC172271M0201 Rev.H...
  • Page 34 2TLC172271M0201 Rev.H...