Bosch DINION IP starlight 7000 HD Installation Manual page 29

Hide thumbs Also See for DINION IP starlight 7000 HD:
Table of Contents

Advertisement

DINION IP starlight 7000
HD
Malfunction
The unit does
not report an
alarm.
Control of
cameras or other
units is not
possible.
The unit is not
operational after
a firmware
upload.
Bosch Security Systems
Possible causes
Alarm source is not
selected.
No alarm response
specified.
The cable connection
between the serial
interface and the
connected unit is not
correct.
The interface
parameters do not
match those of the
other unit connected.
Power failure during
programming by
firmware file.
Incorrect firmware
file.
Troubleshooting | en
Solution
Select possible alarm
sources on the Alarm
sources configuration
page.
Specify the desired
alarm response on
the Alarm
connections
configuration page; if
necessary change the
IP address.
Check all cable
connections and
ensure all plugs are
properly fitted.
Make sure that the
settings of all units
involved are
compatible.
Have the unit
checked by Customer
Service and replace if
necessary.
Enter the IP address
of the unit followed
by /main.htmin your
Web browser and
repeat the upload.
2016.06 | v1.0 | AM18-Q0704
29