Craftsman 73756 Owner's Manual page 8

Ac/dc true rms clamp meter
Table of Contents

Advertisement

Function
Temperature
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital
converter.
Clamp jaw opening
Display
Diode Test
Continuity Check
Temperature Sensor
Input Impedance
AC Response
ACV Bandwidth
Crest Factor
Overrange indication
Auto Power Off
Polarity
Measurement Rate
PEAK
Low Battery Indication
Battery
Operating Temperature
Storage Temperature
Range
Resolution Accuracy
-4 to
1ºF
1400ºF
-20 to
1ºC
760ºC
1.2" (30mm) approx.
3-3/4 digits (4000 counts) backlit
Test current of 0.3mA maximum,
open circuit voltage <3V DC typical
Audible signal will sound if the
resistance is less than 40
(approx.), test current <0.5mA
Requires type K thermocouple
10M (VDC & VAC)
True rms (AAC and VAC)
50Hz to 400Hz
3.0 in 40A and 400A ranges, 1.4 in
800A range (50/60Hz and 5% to
100% of range)
"OL" is displayed
25 minutes (approximately)
Automatic (no indication for
positive); Minus (-) sign for negative
2 times per second, nominal
Captures peaks>1ms
"BAT" is displayed if battery voltage
drops below operating voltage
one 9 volt (NEDA 1604) battery
o
41
o
-4
F to 140
8
± (3% reading + 9ºF)
± (3% reading + 5ºC)
o
o
F to 104
F (5
C to 40
o
o
F (-20
C to 60
o
C)
o
C)