Safety Precautions General Guide Lines When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and semiconductor "chip"...
About lead free solder (PbF) Note: Lead is listed as (Pb) in the periodic table of elements. In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder. The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu). That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
Service Hints How to remove the backcover Remove the 18 fixing screws. (see Fig.5) SCREWS SCREWS Fig.5 How to remove the Pedestal assembly Lay the main unit face down. (see Fig.6) Fig.6 Remove the 4 fixing screws and the pedestal assembly. (see Fig.7) SCREWS Fig.7...
Chassis Board Layout G-BOARD POWER UNIT A-BOARD V-BOARD K-BOARD Board Name Function A-Board Tuner, PC, AVSW, HDMI,CI Slot, Global Core, GENX, AV Terminal, SD Slot, Speaker out, ADV Power Unit Power Supply V-Board Remote Receiver, Cats, R/G LED, Time Led G-Board Side AV Connector K-Board...
Setting Inspection Voltage Confirmation Confirm the following voltages: A board Description Test point Normal mode SUB 1,8V TP5602 1,76V – 1,85V SUB 1,2V TP5601 1,22V – 1,27V SUB 3,3V TP5600 3,19V – 3,39V SUB5V TP1011 4,75V – 5,25V DVDDIO3,3V/ TP4531 3,23V –...
Self-check is used to automatically check the bus lines and hexadecimal code of the TV set. To enter Self-Check mode, keep pressing the down (-/v) button on the TV set and press the STATUS button on the remote control. To exit Self Check, switch off the TV set at the power button. Panasonic 2008LCD 32HD TX-32LXD80 Self Check Complete...
Power LED blinking timing chart Subject Information of LED Flashing timing chart. Contents When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the defective block can be identified by number of blinking of the Power LED on the front panel of the unit. Blinking Blinking timing Contents...
Service Mode Function MPU controls the functions switching for each IICs through IIC bus in this chassis. The following setting and adjustment can be adjusted by remote control in Service Menu How to enter SERVICE While pressing (-/v) button on TV unit, press on the remote control for 3 times within 2 seconds.
SERVICE SERVICE Peaks SOFT 2.107 OPTION 1 Key Command ADJUST Peaks EEP 01.05.0035 OPTION 2 WB-ADJ LSI DATA 0.00.04 OPTION 3 OPTION STBY SOFT 1.01.00 Model ID • TEMP STBY EEP 1.03.00 031e1100 Press the 3/4 button to change the adjustment values or function. SRV-TOOL STBY ROMCOR 1.01.00...
Option Bytes Description OPTION1 ATP Speed Slow (1) / Fast (0) TXT Ch On (1) / Off (0) ID-1 On (1) / Off (0) Macrovision Auto Evaluation On (1) / Off (0) SRS Surround On (1) / Off (0) Teletext Top Off (1) / On (0) Equalizer Not Use...
Adjustment Method Sub-Contrast/White Balance Adjustment Instrument Name Connect to Remarks Remote controller Correlation can be also taken by LCD WB meter (Minolta CS-1000A equivalent) CA-210 or equivalent Comunication jig Computer for external control Procedure Remarks Let the panel standfor more than 3 hours at more than 20 °C.
Replacement Parts List Important Safety Notice Components Identified by mark have special characteristics important for safety. * When replacing any of these components, use only manufacturers specified parts. In case of ordering these spare parts, please always add the complete Model-Type number to your order. RTL (Retention Time Limited) Note: The marking (RTL) indicates that the Retention Time is Limited for this item.
Schematic Diagrams IMPORTANT SAFETY NOTICE Components identified by mark have special characteristics important for safety. When replacing any of these components, use only manufacturers' specified parts. NOTE RESISTOR All resistors are carbon ¼W resistor, unless marked otherwise. Unit of resistance is OHM (Ω) (k=1,000, M=1,000,000) CAPACITORS All capacitors are ceramic 50V unless marked otherwise.