Output Mode And Output Operation - Panasonic dp-100 series Instruction Manual

High performance digital display
Hide thumbs Also See for dp-100 series:
Table of Contents

Advertisement

4
MOUNTING
The sensor mounting bracket (MS-DP1-1) is available as an option.
When mounting the sensor onto the sensor mounting bracket, etc., the
tightening torque should be 0.5N·m or less.
1
No.
Part
1
M3 (length 6mm) screws
with washers
2
Sensor mounting bracket
(MS-DP1-1)
The panel mounting bracket MS-DP1-2 (optional) and MS-DP1-4
(optional), as well as the front cover MS-DP1-3 (optional) and DPX-04
(optional) are also available.
The type of the front cover differs depending on the mounting bracket.
Use MS-DP1-3 for MS-DP1-2, and DPX-04 for MS-DP1-4.
To mount the panel mounting bracket, refer to the Instruction Manual
enclosed with MS-DP1-2 or MS-DP1-4.
5
WIRING
Connection method
Attach the female connector of cable
CN-14A-
to the 4-pin male connector.
Disconnection method
While pressing the release lever, pull out
the connector.
Pin assignment, 4-pin male connector
Pin no.
1
2
3
4
6
I/O CIRCUIT DIAGRAMS
Notes:
When using the analog voltage output, pay careful attention to the
connected device's input impedance.
If the cable is extended, the cable resistance will cause the voltage to
drop.
SEN TRONIC
AG
Produkte, Support und Service
2
Description
Accessory with MS-DP1-1
Optional
Cable with female
connector
CN-14A-C
Release lever
<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]
Terminal name
+V
Comparative output 1
• Standard type: Comparative
output 2
• Multifunction
type:
Analog
voltage output or external input
0V
Rugghölzli 2
CH - 5453 Busslingen
NPN output type
Standard type
Color code of cable with connector
(Brown) +V
(Black)
Comparative output 1
(White) Comparative output 2
(Blue) 0V
Internal circuit
User's circuit
Multifunction type
Color code of cable with connector
(Brown) +V
5V
(White)
Analog voltage output
or external input
1k
(Black) Comparative output 1
(Blue) 0V
Internal circuit
Users' circuit
PNP output type
Standard type
Color code of cable with connector
(Brown) +V
(Black) Comparative output 1
(White) Comparative output 2
(Blue) 0V
Internal circuit
User's circuit
Multifunction type
Color code of cable with connector
(Brown) +V
(Black) Comparative output 1
1k
(White)
Analog voltage output
or external input
(Blue) 0V
Internal circuit
User's circuit
7

OUTPUT MODE AND OUTPUT OPERATION

The EASY mode, hysteresis mode or window comparator mode can be
selected as the output mode for comparative output 1 and, for the standard
type DP-100, comparative output 2.
For details, see page 5, section 10, MENU SETTING MODE.
Easy mode
The comparative output is turned ON or OFF (depending on the N.O./N.C.
setting) when the threshold is reached. The tolerance of the threshold is
specified by the hysteresis setting. For details, see page 6, section 11, PRO
MODE.
P
0
Comparative
ON
output
OFF
Notes:
• Hysteresis can be fixed in 8 levels.
For details, see page 6, section 11, PRO MODE.
• P-1 is displayed for comparative output 1 and P-2 for
comparative output 2 on the sub-display.
2
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
Load
Load
+
12 to 24V DC
100mA max.
_
±10%
100mA max.
Load
+
12 to 24V DC
_
±10%
100mA max.
100mA max.
+
12 to 24V DC
100mA max.
_
±10%
Load
Load
100mA max.
+
12 to 24V DC
_
±10%
Load
H (Hysteresis)
mailbox@sentronic.com
www.sentronic.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents