Siemens 6SE2101–1AA01 Operating Manual page 28

6se21 series simovert p
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Description
Number
P21
Serial Interface Address
P22
Serial Interface Parity
& Baud Rate
P23
Digital Input Response Speed
P24
Fixed Frequency Mode Selection
P25
First Fixed Frequency
P26
Second Fixed Frequency
5/11
Display
Setting
Notes
(Factory
Setting)
000 –
Sets the address of the inverter when the serial
030
interface is used. (See section 7 for further details.)
(000)
Sets the parity and baud rate of the serial address:
Parity
000
Even
001
Even
002
Even
003
Odd
004
Odd
005
Odd
006
Ignored
007
Ignored
008
Ignored
Note:
The master unit must still transmit a parity
bit in each byte.
(000)
000
15 ms debounce of digital inputs
(for relays or switches).
001
No debounce
– suitable for transistor–controlled inputs in control
systems which require a fast response.
(000)
000
Normal operation – fixed frequency disabled.
001
Selects fixed frequencies. In this mode the
inverter only outputs fixed frequencies, ramping
between the fixed frequencies at rates set by P02
and P03. The fixed frequencies are selected using
and
terminals (X11.17 and X11.18) in
accordance with the following table:
(1 = 7 – 33 V)
(0 = < 7 V)
002
Allows three fixed frequencies (P26, P27 & P28)
and one analogue set–point in accordance with
the following table:
Note:
002 is only valid if P04 is set to 000, 001,
002, 007, 008 or 009.
(000)
00.0 –
Fixed frequency.
400
(00.0)
00.0 –
Fixed frequency.
400
(00.0)
English
USS Only
Baud Rate
(Even Parity)
2400
9600
4800
9600
9600
9600
2400
9600
4800
2400
9600
4800
2400
9600
4800
9600
9600
9600
Freq
Freq
Freq
1
2
3
0
1
0
0
0
1
Analogue
Freq
Freq
Freq
2
3
0
0
1
0
1
0
Freq
4
1
1
Freq
4
1
1