Production Capacity - Haier HI50IB20SS User Manual

Automatic undercounter ice maker
Table of Contents

Advertisement

InStAllAtIon InStRUctIonS cont.
• This ice maker should be properly
installed by qualified personnel.
• To ensure proper ventilation for your
ice maker, the front of the unit must be
completely unobstructed.
• When installing the ice maker under
a counter, follow the recommended
spacing dimensions shown. Allow at
least 4" (102 mm) clearance at rear,
and 1" (25 mm) at top and sides for
proper air circulation. The installation
should allow the ice maker to be pulled
forward for servicing if necessary.
• Choose a well ventilated area with
temperatures above 50°F (10°C) and
below 100°F (38°C).This unit MUST be
installed in an area protected from the
Normal operating ambient temperature should be between 50°F (10°C)
to 100°F (38°C). Normal operating water temperature should be between
41°F (5°C) and 90°F (32°C). Operation of the ice maker for extended
periods out- side of these normal temperature ranges may affect
• It is strongly recommended that a
water filter be used. A filter, if it is of
the proper type, can remove taste
and odors as well as particles. Some
water is very hard, and softened water
may result in white, mushy cubes that
stick together. Deionized water is not
recommended.
• The ice maker must be installed with
electrical and water connections in
accordance with all state and local
codes.
elements, such as wind, rain, water
spray or drips.
• The unit should not be located next
to ovens, grills or other high heat
sources.
• Installation of the ice maker requires
a cold water supply inlet of ¼-in.
(6.35mm) soft copper tubing with a
shut-off valve.
• The ice maker requires a continuous
water supply with a minimum pressure
of 15 psig and a static pressure not to
exceed 80 psig. The temperature of
the water feeding into the ice maker
should be between 41°F (5°C) and 90°F
(32°C) for proper operation.
WARnIng

production capacity.

• The unit should be located on a firm
and level surface. It is important for
the ice maker to be leveled in order
to work properly. If needed, you can
adjust the height of the ice maker by
revolving the caster. See the Leveling
the Ice Maker section.
• A standard electrical supply (115V
AC, 60Hz, 15A), properly grounded in
accordance with the National Electrical
Code and local codes and ordinances,
is required.
Page 9 • Set uP & uSe