5.5 Specifications
5.5.1 Specifications
General Description
Item
System Capacity
Power Supplies
Dialling
SMDR
(Station Message
Detail Recording)
Appendix
KX-TD816
Outside lines
Extension lines
(Extension lines with XDP
KX-TD1232
Outside lines
Extension lines
(Extension lines with XDP
Primary
Secondary
Power Failure
Outward/Internal
Mode Conversion
Interface
Output Equipment
Detail Recording
Description
Basic
Expansion
4
8
8
16
16
32
8
38
16
32
32
64
KX-TD816BX: 110 VAC - 115 VAC / 200 VAC / 220
VAC / 240 VAC, 50 Hz / 60 Hz
KX-TD816HK: 220 VAC - 230 VAC, 50 Hz
KX-TD1232(D)BX / KX-TD1232HK / KX-TD1232ML /
KX-TDN1232: 220 VAC - 240 VAC, 50 Hz / 60 Hz
KX-TD1232X: 110 VAC - 120 VAC, 50 Hz / 60 Hz
Station Supply Volt : 30 V
Circuit Volt:
5 V,
15 V
•
Memory backup duration : seven years with a
factory-provided lithium battery
•
4 outside lines max. for KX-TD816 and 6 outside
lines max. for KX-TD1232 automatically assigned
to stations (Power Failure Transfer)
•
System operation for about three hours using
recommended batteries (consisting of two 12
VDC car batteries)
Dial Pulse (DP) 10 pps, 20 pps, Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
Serial Interface (RS-232C)
Printer
Date, Time, Extension Number, Outside Line
Number, Dial Number (Timed Reminder, Caller ID),
Ring Duration, Call Duration, Account Code,
Condition Code, Charge Fee
5.5 Specifications
System Connection
—
—
—)
38
64
128)
209