Percent base data =
3
■ Set parameters of PG sensor
Table 3-7. Parameters of PG sensor
Title
9
F375
F376
F377
F379
(1)
[F375: PG pulses number] is the number of encoder output pulses per one motor rotation.
(2)
[F379: PG option voltage] is the supplied voltage to PG option.
(3)
[F376: PG select], set as follows:
3. Functional Description
InputPulsefrequency
PG input pulse x Maximumfrequency
Frequency
command
[F237]
80Hz
[F235]
0Hz
[F234]
0%
Figure 4 Percent base data and frequency command value
Function Name
PG pulses number
PG select
PG option disconnection detection
PG option voltage
x 100 [%]
Percent base data
[F236]
100%
Adjustment Range
1 - 9999
0: PTI (Command) – PTI (FB)
1: PTI (Command) – Digital option (FB)
2 - 5: -
6: Digital option (Command) - Non FB
7 - 9: -
10: PTI (Command) - PTI (FB inversion)
11: PTI (Command) - Digital option (FB
inversion)
12 - 15: -
16: Digital option (Command inversion)
- Non FB
0: Disabled
1: Enabled
0: 5V
1: 12V
2: 24V
3-8
E6582148
Setting at
Shipment
1000
0
0