2.26 RESTART PROCEDURE

Legend
A. Domestic Hot Water Temperature Knob
B. Central Heating Temperature Knob
C. Mode Knob
D. Boiler status Display
E. Burner 'on' Indicator
F. Restart Button
G. Preheat On/Off Button
H. Pressure Gauge

2.27 ACCESSING THE INSTALLER MODE

To access Installer Mode press the "PREHEAT" and "RESTART" Buttons
together for more than 5s.
1. The last 3 faults will be shown
See Frame 4.1 for Fault Code descriptions
2. "SL" will be shown
To run the burner at minimum rate press "RESTART", otherwise
press "PREHEAT".
3. "SH" will be shown
To run the burner at maximum rate press "RESTART", otherwise
press "PREHEAT".
4. "VF" will be shown
To activate the venting function press "RESTART", otherwise press
"PREHEAT".

2.28 HANDING OVER

After completing the installation and commissioning of the system the installer should hand over to the householder by
the following actions:
1. Hand the User Instructions to the householder and
explain his/her responsibilities under the relevant national
regulations.
2. Explain and demonstrate the lighting and shutting down
procedures.
3. The operation of the boiler and the use and adjustment of all
system controls should be fully explained to the householder,
to ensure the greatest possible fuel economy consistent with
the household requirements of both heating and hot water
consumption.
Advise the User of the precautions necessary to prevent
damage to the system and to the building, in the event of the
system remaining inoperative during frosty conditions.
4. Explain the function and the use of the boiler heating and
domestic hot water controls.
Explain that due to system variations and seasonal
temperature fluctuations DHW flow rates/temperature
rise will vary, requiring adjustment at the draw off tap. It
is therefore necessary to draw the user's attention to the
section in the Users Instructions titled "Control of Water
Temperature" and the following statement:
"Additionally, the temperature can be controlled by the
user via the draw-off tap: the lower the rate the higher
the temperature, and vice versa".
5. Explain the function of the boiler fault mode.
Emphasise that if a fault is indicated refer to "Fault Codes" in
the User Guide.
38
SECTION 2 - INSTALLATION
To restart the boiler, press the RESTART button (F).
MIN
A
H
5. "dU" will be shown
6. "P1" will be shown
7. "P7" will be shown
6. Explain and demonstrate the function of timers and
7. If a timer is fitted draw attention to the timer Users
8. Loss of system water pressure
9. Explain boiler restart procedure. Refer to Section 2.26.
10. After installation and commissioning please complete
IMPORTANT
11. A comprehensive service should be carried out ANNUALLY.
12. Inform the householder of the guarantee/registration found
ºC
HOT WATER
PREHEAT
ON
MAX
MIN
PREHEAT
RESTART
D
G
F
E
The venting function runs for 5 minutes before automatically
returning to normal operation
The diverter valve moves between CH and DHW every 30s
The Pump alternates between being on for 50s and then off for 10s
To move the diverter valve to mid-position for replacement press
"RESTART", otherwise press Preheat
To set the minimum CH pump speed to 100% press "RESTART",
otherwise press "PREHEAT".
To set the minimum CH pump speed to 70% (default) press
"RESTART", otherwise press "PREHEAT" to Exit
temperature controls, radiator valves etc., for the economic
use of the system.
Instructions and hand them to the householder.
Explain that the dial on the control panel front indicates
the central heating system pressure and that if the normal
COLD pressure of the system is seen to decrease over a
period of time then a water leak is indicated. Explain the re-
pressurising procedure and if unable to re-pressurise or if the
pressure continues to drop a registered local heating installer
should be consulted. Refer to Section 2.17.
the
Commissioning Checklist before
handover to the customer. For IE, it is necessary to complete
a "Declaration of Conformity" to indicate compliance to
I.S. 813:2002.
Stress the importance of regular servicing by a Gas Safe
Registered Engineer. In IE servicing work must be carried out
by a Registered Gas Installer (RGII).
within the envelope pack and the requirement to register it to
receive the full benefit of the warranty.