Knob Parameter Adjustment
1
Address
2
Level
6
When setting the tally type, set the following
parameter.
Knob Parameter Adjustment
3
Type
a) 1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, 8:G4, 9:R5, 10:G5, 11:R6,
12:G6, 13:R7, 14:G7, 15:R8, and 16:G8 (R is an abbreviation of
"Red Tally," and G of "Green Tally").
7
Press [Execute].
This makes the parallel tally settings, in accordance
with the settings in steps 1 to 6.

Deleting Parallel Tally Settings

1
In the Router/Tally >Parallel Tally menu, using any of
the following methods, select the parallel tally whose
settings you want to delete.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knobs.
Knob Parameter Adjustment
1
Slot No
2
Port No
2
Press [Clear].
658

Serial Tally Settings (Serial Tally Menu)

Setting values
Destination
1 to 1024
address
Destination level
1 to 8
Setting values
a)
1 to 16
Tally type
Setting values
Parallel tally slot
2 to 6
number
Parallel tally port
1 to 54
number
Serial Tally Settings
(Serial Tally Menu)
To make serial tally settings, display the Router/Tally
>Serial Tally menu.
Make the serial tally settings, including tally type and
source address for each serial tally port.
To display the Serial Tally menu
In the Engineering Setup menu, select VF6 'Router/Tally'
and HF7 'Serial Tally.'
The serial tally settings appear in the status area.
Setting or Changing the Serial Tally
Settings
1
In the <Serial Tally Port> group of the Router/Tally
>Serial Tally menu, select the port to which the setting
applies.
2
In the <Tally Group> group, select the tally group.
3
In the <Tally Type> group, press the tally types to
select. You can select up to four.
Notes
The selectable tally types depend on the settings in
step 2.
4
In the <Tally Data Size> group, press one of the
following to select the data size.
128 Bit: 128 bits
256 Bit: 256 bits
Making the Serial Tally Source
Address Settings
To set the serial tally source address for each port, use the
following procedure.
1
In the Router/Tally >Serial Tally menu, press [Source
Assign].
The Source Assign menu appears.
In the status area, the tally types and source address set
for the serial tally port appear.
2
In the <Serial Tally Port> group, select the port to
which the setting applies.