Siemens SINAMICS S120 Manual page 207

Sinamics family modular motion control drives
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

LED
Color
Orange
OUT>5 V
-
Orange
MOD
-
AC Drive
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
Status
Flashing
Firmware CRC error.
2 Hz
off
Electronics power supply is missing or outside
permissible tolerance range.
Power supply v5 V
Continuous
Electronics power supply for measuring system
available.
Power supply >5 V.
Important:
Make sure that the connected encoder can be
operated with a 24 V power supply. If an encoder
that is designed for a 5 V supply is operated with a
24 V supply, this can destroy the encoder
electronics.
off
Reserved
6.3 Control Unit CU310 PN (PROFINET)
Description, cause
Control Units
Remedy
Make sure that the
CompactFlash card
has been inserted
properly.
Replace the
CompactFlash Card.
Replace Control Unit.
Carry-out a POWER
ON.
-
-
-