5. Upper Feed Guide Plate

1) Remove the upper cover.
(Page 3-2)
2) Remove the upper reading unit.
(Page 3-14)
3) Open the front unit, unhook the 3 pairs of
fitting parts
at the bottom, and then
1
push the plate out slightly. Completely
open the front unit, and pull out the
bottom of the upper feed guide plate
Next, unhook the pair of fitting parts in
the center
and the 4 pairs of fitting
3
parts at the top
upper feed guide plate. You should
completely detach the fitting parts.
Note:For the fitting parts on the bottom side,
unhook the left and right fitting parts
by pushing while bending the plate
downwards, and unhook the central
fitting part by pushing while bending
upwards.
Figure 3-208
COPYRIGHT © CANON ELECTRONICS INC. 2011
2
and remove the
4
CANON DR-M160 FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
Notes on assembling
All of the fitting parts should be fully
seated. There should not be any raised
parts.
The reading unit cable should come out
through the hole.
If the guide plate has been deformed too
much and does not return to its original
shape and affects feeding, either repair
.
it or replace it with a new part.