Advertisement

7847i/7847i-E Installation and Setup Guide
NOTE: The Remote Access option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
PROMPTS
Remote Access Y/N
29
(N)_
Direct Wire
Y/N
30
(N)_
Keypad Address
31
(28)_
Supervision
32
(24 Hours)_
Old Alarm Time
33
10 Minutes_
3-6
ENTRY
OPTIONS
[Y], [N]
[Y], [N]
[01-30]
• 24 Hours
• 1 Hour
• US UL Line
(6 Min)
• CN UL Line
Lvl 3 (3 Min)
• US UL Line
(90 Sec)
• CN UL Line
Lvl 4 (90 Sec)
• CN UL Line
Lvl 5 (75 Sec)
• None
• 30 Day
•10 Minutes
• 15 Minutes
• 30 Minutes
• 1 Hour
• 2 Hours
• 4 Hours
• 8 Hours
• 12 Hours
• 24 Hours
DESCRIPTION
Press [Y] to allow the end user to access their system
via a website. Availability of this service is controlled
by the dealer via the web-based programming tool on
the AlarmNet Direct website.
Applies only to VISTA-128BP/250BP and FBP Series
controls, and FA1600C and FA1700C Series controls.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 29: Remote Access is disabled,
skip to Prompt 32: "Supervision."
Must be programmed if using either the Remote Access
feature or Direct Wire downloading. Enter the
appropriate device address.
NOTES:
1. This address must also be programmed as an alpha
keypad in the control panel or an AUI (Advanced
User Interface) type device, if a full enhanced graphic
interface to the system is desired and the control
panel supports it. DO NOT connect an actual
keypad (or any other device) assigned to this address.
2. If using a compatible LynxR-I series control (when
available), this address must be set to "1."
3. This address must be unique from the "Device
Address" entered in Prompt 28.
The AlarmNet network must hear at least one
supervisory message from the module during this
supervision period; otherwise, AlarmNet notifies the
central station that a communication failure has
occurred. (If the supervision period is changed after
registration, you must re-register the module.)
Press the [space] key to scroll through choices.
Sets how long an undeliverable alarm is retried for
delivery to the central station. If the message is not
validated, it is retried until the old alarm time is
reached or the message is validated.
Press the [space] key to scroll through choices.
UL NOTE: Must be 10 minutes.