Siemens SCALANCE XC-200 Operating Instructions Manual

Siemens SCALANCE XC-200 Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XC-200:
Table of Contents

Advertisement

SIMATIC NET
Industrial Ethernet switches
SCALANCE XC-200
Operating Instructions
07/2016
C79000-G8976-C442-01
___________________
Introduction
___________________
Safety notices
___________________
Description of the device
___________________
Mounting
___________________
Connecting up
___________________
Maintenance and
troubleshooting
___________________
Technical specifications
___________________
Dimension drawings
___________________
Certifications and approvals
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XC-200

  • Page 1 ___________________ Introduction ___________________ Safety notices ___________________ SIMATIC NET Description of the device ___________________ Mounting Industrial Ethernet switches SCALANCE XC-200 ___________________ Connecting up ___________________ Maintenance and troubleshooting Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Certifications and approvals 07/2016 C79000-G8976-C442-01...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Installation on a standard S7-300 rail ..................41 Installation on a standard S7-1500 rail ................... 42 Wall mounting ......................... 44 Changing the position of the securing bar ................45 General notes for SFP transceivers ..................46 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 4 Technical specifications of the SCALANCE XC224 .............. 69 Mechanical stability (in operation)..................70 Cable lengths ......................... 71 Switching properties ....................... 72 Dimension drawings ..........................73 Dimension drawings SCALANCE XC-200 ................73 Certifications and approvals ........................77 Index ..............................83 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 5: Introduction

    ● SCALANCE XC208 ● SCALANCE XC216 ● SCALANCE XC224 Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE XC-200 product group named above in the section on validity. Designations used Classification Description Terms used Product line The product line includes all devices and variants of all product groups.
  • Page 6 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
  • Page 7 ● On the Internet under the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
  • Page 8 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 9 Introduction Trademarks The following and possibly other names not identified by the registered trademark sign ® registered trademarks of Siemens AG: SIMATIC NET, SCALANCE, C-PLUG, OLM SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 10 Introduction SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 11: Safety Notices

    This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 12: Recommendations On Network Security

    ● Keep the firmware up to date. Check regularly for security updates for the device. You will find information on this on the Internet pages Industrial Security (http://www.siemens.com/industrialsecurity). ● Inform yourself regularly about security recommendations by Siemens ProductCERTHotspot-Text (http://www.siemens.com/cert/en/cert-security- advisories.htm).
  • Page 13 ● Verify certificates and fingerprints on the server and client to prevent "man in the middle" attacks. ● It is recommended that you use certificates with a key length of at least 2048 bits. ● Change certificates and keys immediately, if there is a suspicion of compromise. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 14 ● Restrict the services and protocols available to the outside to a minimum. ● For the DCP function, enable the "Read Only" mode after commissioning. ● If you use RADIUS for management access to the device, activate secure protocols and services. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 15 Open (when con- Open figured) HTTP TCP/80 Open (when con- Open figured) HTTPS TCP/443 Open Open SNMP UDP/161 Open (when con- Open Yes (when config- figured) ured) PROFINET UDP/34964, Open Open UDP/49154 - UDP/49157 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 16 Port status Factory setting Authentication Encryption TELNET TCP/23 Open (when con- Open figured) EtherNet/IP TCP/44818, Open (when con- Closed UDP/2222, figured) (Open with Ether- UDP/44818 net/IP variants) DHCP UDP/67, Open (when con- Closed UDP/68 figured) SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 17: Description Of The Device

    6GK5 216-0BA00-2AC2 SCALANCE XC224 24 x 10/100 Mbps RJ-45 ports 6GK5 224-0BA00-2AC2 Type designation The type designation of a SCALANCE XC-200 is made up of several parts that have the following meaning: Interfaces of devices with optical connectors: Interface Property...
  • Page 18: Accessories

    Description of the device 3.1 Product overview Components of the product The following components are supplied with a SCALANCE XC-200: ● One IE switch ● A 4-pin terminal block for the power supply ● A 2-pin terminal block for the signaling contact ●...
  • Page 19 Restriction for pluggable transceivers If you use pluggable transceivers of the types LH, LH+, ELH or ELH200, the maximum ambient temperature is reduced to 60 °C. Spare parts The following spare parts are available for SCALANCE XC-200: Component Description Article number...
  • Page 20: Device Views

    ③ ⑨ Grounding screw Serial interface ④ ⑩ Knurled screw "SELECT / SET" button ⑤ ⑪ Securing bar LED display ⑥ ⑫ Levering aid for moving the securing bar with C-PLUG slot a screwdriver SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 21: Device View Of A Scalance Xc206-2 (Sc)

    ③ ⑨ Grounding screw Serial interface ④ ⑩ Knurled screw "SELECT / SET" button ⑤ ⑪ Securing bar LED display ⑥ ⑫ Levering aid for moving the securing bar with C-PLUG slot a screwdriver SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 22: Device View Of A Scalance Xc206-2Sfp

    ③ ⑨ Grounding screw Serial interface ④ ⑩ Knurled screw "SELECT / SET" button ⑤ ⑪ Securing bar LED display ⑥ ⑫ Levering aid for moving the securing bar with C-PLUG slot a screwdriver SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 23: Device View Of A Scalance Xc208

    Grounding screw Serial interface ③ ⑨ Knurled screw "SELECT / SET" button ④ ⑩ Securing bar LED display ⑤ ⑪ Levering aid for moving the securing bar with C-PLUG slot a screwdriver ⑥ Power supply SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 24: Device View Of A Scalance Xc216

    Grounding screw Serial interface ③ ⑨ Knurled screw "SELECT / SET" button ④ ⑩ Securing bar LED display ⑤ ⑪ Levering aid for moving the securing bar with C-PLUG slot a screwdriver ⑥ Power supply SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 25: Device View Of A Scalance Xc224

    Grounding screw Serial interface ③ ⑨ Knurled screw "SELECT / SET" button ④ ⑩ Securing bar LED display ⑤ ⑪ Levering aid for moving the securing bar with C-PLUG slot a screwdriver ⑥ Power supply SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 26: Select / Set Button

    Resetting the device to factory defaults NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 27 If you release the button before the 12 seconds have elapsed, the reset is canceled. Enabling and disabling the button In the configuration, you can enable or disable the button function. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 28 The redundancy manager and media redundancy are disabled. Result: After enabling the redundancy manager, media redundancy is also enabled. – Initial situation: The redundancy manager and media redundancy are enabled. Result: After disabling the redundancy manager, media redundancy remains enabled. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 29: Led Display

    The device is a redundancy manager. The ring is working without problems, monitoring is activated. Green Flashing The device is a redundancy manager. An interruption has been detected on the ring and the device has switched through. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 30: Sb" Led

    Depending on the set display mode, the "L1", "L2" LEDs and the port LEDs show different information. LED color LED status Meaning DM1 LED DM2 LED Display mode A Green Display mode B Green Display mode C Green Display mode D SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 31: Leds "L1" And "L2

    Power supply is not monitored. If the power supply falls below 9.6 V, the signaling contact does not respond. Green Power supply is monitored. If the power supply falls below 9.6 V, the signaling contact re- sponds. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 32: Port Leds

    LED goes off. Meaning in display mode C In display mode C, the port LEDs indicate the mode. LED color LED status Meaning Port operating in half duplex mode Green Port operating in full duplex mode SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 33: C-Plug

    MAC address set by the vendor. A C-PLUG stores the current information about the configuration of a device. Note The device can also be operated without a C-PLUG. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 34 ● Web Based Management (WBM) ● SNMP ● Command Line Interface (CLI) ● PROFINET diagnostics The user then has the choice of either removing the C-PLUG again or selecting the option to reformat the C-PLUG. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 35: Replacing The C-Plug

    Removing a C-PLUG 1. Turn off the power to the device. 2. Insert a screwdriver between the front edge of the C-PLUG (A) and the slot and release the C-PLUG. 3. Remove the C-PLUG. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 36: Near Field Communication

    SCALANCE XC-200. Position Figure 3-2 Position of NFC on the SCALANCE XC-200 in the bottom left corner of the LED display. Reading out information To read out information via the SCALANCE XC-200 using NFC, follow the steps below: 1.
  • Page 37: Mounting

    Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING The device is suitable only for operation in the interior. WARNING The device may only be operated in an environment with pollution degree 1 or 2 (see IEC 60664-1). SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 38 Warming and premature aging of the network component due to direct sunlight Direct sunlight can heat up the device and can lead to premature aging of the network component and its cabling. Provide suitable shade to protect the network component against direct sunlight. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 39: Types Of Installation

    Mounting 4.2 Types of installation Types of installation Types of installation The SCALANCE XC-200 can be installed in the following ways: ● DIN rail ● S7-300 standard rail ● S7-1500 standard rail ● Wall mounting Installation clearance Keep to the minimum clearances so that the convection ventilation of the device is not blocked.
  • Page 40: Mounting On Din Rails

    5. Connect the electrical connecting cables, refer to the section "Connecting up (Page 47)". Removal To remove the device from a DIN rail, follow the steps below: 1. Disconnect all connected cables. 2. If necessary, loosen the knurled screw with your hand or a screwdriver. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 41: Installation On A Standard S7-300 Rail

    4. When you tighten the knurled screw. you cannot release the securing bar (torque 0.5 Nm). The device is additionally fixed. 5. Connect the electrical connecting cables, refer to the section "Connecting up (Page 47)". SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 42: Installation On A Standard S7-1500 Rail

    1. Place the first housing guide of the device on the top edge of the standard rail. 2. Swing the device down towards the back against the mounting rail. 3. Loosen the knurled screw with your hand or a screwdriver. The spring mounted securing bar locks in place. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 43 2. If necessary, loosen the knurled screw with your hand or a screwdriver. 3. Lever the securing bar down using a screwdriver as far as it will go. 4. Remove the device from the mounting rail with the bar pulled. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 44: Wall Mounting

    3. Hang the device with the keyhole hanging mechanism on the rear on the screw. 4. Fix the device to the wall with the lower screw. 5. Connect the electrical connecting cables, refer to the section "Connecting up (Page 47)". SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 45: Changing The Position Of The Securing Bar

    The securing bar is fixed in the wall mounting position. 5. Remove the pin. Wall mounting position - rail mounting position To move the securing bar from the wall mounting position to the rail mounting position, loosen the knurled screw. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 46: General Notes For Sfp Transceivers

    WARNING Use only approved SFP transceivers If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee that the device will function according to its specifications. If you use unapproved SFP transceivers, this can lead to the following problems: •...
  • Page 47: Connecting Up

    Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 48 Do not connect any electrical connectors directly to the telephone network (telephone network voltage) or a WAN (Wide Area Network). WARNING EXPLOSION HAZARD Do not press the SELECT/SET button when there is an explosive atmosphere. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 49: Wiring Rules

    ** See note "Wire end ferrules" Note Wire end ferrules Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp cross sections. Crimp shapes with wave-shaped profile are unsuitable. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 50: Power Supply

    Manufacturer: DEHN+SOEHNE GmbH+Co. KG, Hans-Dehn-Str.1, Postfach 1640, D92306 Neumarkt, Germany Operate the SCALANCE XC-200 with suitable overvoltage protection. Note The device can be disconnected from the power supply by pulling off the terminal block. Information on the power supply ●...
  • Page 51 5.3 Power supply Position and assignment Figure 5-1 Position of the power supply based on the example of the SCALANCE XC208 and the assignment of the terminal block Contact Assignment 24 VDC Ground Ground 24 VDC SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 52: Signaling Contact

    Higher voltages or currents can damage the device. Position and assignment Figure 5-2 Position of the signaling contact based on the example of the SCALANCE XC208 and the assignment of the terminal block Contact Assignment Fault contact 1 Fault contact 2 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 53: Serial Interface

    D-sub female connector. The connecting cable for the serial interface can be ordered as an accessory. Position and assignment Figure 5-3 Position and pin assignment of the serial interface (RJ-11 jack), for example on the SCALANCE XC208 as well as the pin assignment D-sub socket. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 54 RD (Receive Data) SG (Signal Ground) Note Pin assignment of the RJ-11 jack on the device The RJ-11 jack on the device has a pinout to match the RJ-11 plug of the connecting cable. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 55: Functional Ground

    With automation components, functional ground also ensures interference-free operation of a controller. Via the functional ground, interference currents coupled in via the connecting cables are discharged to ground. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 56 Connecting up 5.6 Functional ground SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 57: Maintenance And Troubleshooting

    Maintenance and troubleshooting Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Procedure with Microsoft Windows Using TFTP, you can supply a device with new firmware even when it cannot be reached using WBM or CLI.
  • Page 58: Restoring The Factory Settings

    5. The device starts automatically with the factory defaults. Restoring the factory defaults during operation You can also reset the device to the factory defaults during operation, see section "SELECT / SET button (Page 26)". SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 59: Technical Specifications

    9.6 to 31.2 VDC Safe Extra Low Voltage (SELV) Design Terminal block, 4 terminals Properties Implemented redundantly Current consumption 12 VDC 500 mA 24 VDC 250 mA Effective power loss Fusing 2.5 A / 125 V SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 60 45 seconds Max. number of learnable MAC 2048 addresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues Note the wiring rules (Page 49). SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 61: Technical Specifications Scalance Xc206-2 (Sc)

    12 VDC 500 mA 24 VDC 250 mA Effective power loss Fusing 2.5 A / 125 V Signaling contact Quantity Design Terminal block, 2 terminals Permitted voltage range 24 VDC Load capability max. 100 mA SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 62 45 seconds Max. number of learnable MAC 2048 addresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues Note the wiring rules (Page 49). SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 63: Technical Specifications Scalance Xc206-2Sfp

    Relative humidity During operation at 25 ℃ ≤ 95 % no condensation Housing, dimensions and weight Design compact Housing material Basic housing Die cast aluminum, powder coated Front cover Polycarbonate (PC-GF10) Degree of protection IP20 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 64 "Introduction" Additional documentation (Page 5). Depending on which pluggable transceiver you use, the maximum ambient temperature can change, see section "Accessories", Pluggable transceivers SFP (Page 18)". SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 65: Technical Specifications Of The Scalance Xc208

    Design compact Housing material Basic housing Die cast aluminum, powder coated Front cover Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 60 x 147 x 125 mm Weight 520 g SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 66 Max. number of learnable MAC ad- 2048 dresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues Note the wiring rules (Page 49). SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 67: Technical Specifications Of The Scalance Xc216

    Design compact Housing material Basic housing Die cast aluminum, powder coated Front cover Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 120 x 147 x 125 mm Weight 800 g SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 68 45 seconds Max. number of learnable MAC 2048 addresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues Note the wiring rules (Page 49). SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 69: Technical Specifications Of The Scalance Xc224

    Design compact Housing material Basic housing Die cast aluminum, powder coated Front cover Polycarbonate (PC-GF10) Degree of protection IP20 Dimensions (W x H x D) 120 x 147 x 125 mm Weight 880 g SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 70: Mechanical Stability (In Operation)

    85 - 150 Hz: 1 g 1 octave/min, 20 sweeps SCALANCE XC206-2 (ST/BFOC) ● ● SCALANCE XC206-2 (SC) ● ● SCALANCE XC206-2SFP ● ● SCALANCE XC208 ● ● SCALANCE XC216 ● ● SCALANCE XC224 ● ● SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 71: Cable Lengths

    0 to 90 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE FC TP standard cable 0 to 100 m with IE FC RJ-45 Plug 180 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 72: Switching Properties

    8127 Note The number of SCALANCE XC-200 modules connected in a line influences the entire frame delay. When a frame passes through the IE switch, this is delayed by the store-and-forward function of the SCALANCE XC-200 by 10-130 microseconds (at 100 Mbps).
  • Page 73: Dimension Drawings

    Dimension drawings Dimension drawings SCALANCE XC-200 Note Dimensions are specified in mm. Front view SCALANCE XC206-2 (ST/BFOC), SCALANCE XC206-2 (SC), SCALANCE XC206-2SFP and SCALANCE XC208 ① Securing bar in the rail mounting position ② Securing bar in the wall mounting position (as supplied).
  • Page 74 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 Front view SCALANCE XC216 and SCALANCE XC224 ① Securing bar in the rail mounting position ② Securing bar in the wall mounting position (as supplied). Figure 8-2 Width and height SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 75 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 Side view of the SCALANCE XC-200 ① Securing bar in the rail mounting position ② Securing bar in the wall mounting position (as supplied). Figure 8-3 Depth SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 76 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 Drilling template for wall mounting Figure 8-4 Drilling template with securing bar in the wall mounting position (as supplied) SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 77: Certifications And Approvals

    You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 78 You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/33118389/134200). The EC Declaration of Conformity is available for all responsible authorities at:...
  • Page 79 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”.
  • Page 80 ● CAN/CSA-IEC 61010-2-201 Report no. E85972 cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● CSA C22.2 No. 60950-1-03 Report no. E115352 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 81 바라며, 가정 외의 지역에서 사용하는것을 목적으로 합니다. Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 82 ● SCALANCE XC208 SCALANCE XC216 SCALANCE XC224 Figure 9-1 FDA and IEC approvals CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 83: Index

    Factory settings, 26, 58 Fault mask, 28 Fault/error status, 30 Permitted ambient conditions, 60, 62, 63, 65, 67, 69 Firmware, 30, 57 Permitted environmental conditions, 19 PLUG, 33 Pluggable transceiver SFP, 6, 18, 19, 19 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...
  • Page 84: Scalance Xc

    Startup phase, 27, 30, 58 Switching properties, 60, 62, 64, 66, 68, 70 System manual, 6, 77 Web Based Management (WBM), 34, 57 Weight, 60, 62, 63, 65, 67, 69 Wiring rules, 50, 52 SCALANCE XC-200 Operating Instructions, 07/2016, C79000-G8976-C442-01...

Table of Contents