1. OUTLINE
This manual explains the sample screens of GOT2000 connected to a MELSEC-Q Series PLC (Q06UDEHCPU)
via Ethernet. The sample screens can be used for monitoring the status of each axis and the buffer memory
(including current values and alarms) of Simple Motion Module (QD77MS16).
2. SYSTEM CONFIGURATION
GOT2000
GT27**-V (640 X 480)
Interface:
Standard I/F (Ethernet)
SD card *1
Battery (GT11-50BAT) *2
*1: The SD card is used for the document display function.
*2: The battery is used for the backup of the clock data. (The battery is provided with the GOT as standard.)
*3: For more details about the cable, please refer to the "GOT2000 Series Connection Manual (Mitsubishi
Products)".
3. GOT
3.1 System Applications That Are Automatically Selected
Type
Standard Function
Communication Driver
Extended Function
3.2 Controller Setting of Screen Design Software
Detail Setting
GOT NET No.
GOT Station No.
GOT Ethernet Setting
GOT Communication Port No.
Retry (Times)
Startup Time (Sec)
Timeout Time (Sec)
Delay Time (ms)
GOT Ethernet Setting
Reflect GOT Ethernet setting in the GOT
GOT IP Address
Subnet Mask
Default Gateway
Peripheral S/W Communication Port No.
Transparent Port No.
Standard System Application
Standard Font
Ethernet Connection
Standard Font
Outline Font
Document Display
Item
Item
Ethernet cable *3
System application name
Japanese
Ethernet (MELSEC), Q17nNC, CRnD-700, Gateway
Chinese (Simplified)
Alphanumeric/Kana
Gothic
Japanese (Kanji)
Chinese (Simplified)
Set value
1
2
Refer to table below
5001
3
3
3
0
Set value
Checked
192.168.3.18
255.255.255.0
0.0.0.0
5015
5014
5/35
Q06UDEHCPU
QD77MS16
Servo Amplifier
Remarks
Remarks