Summary of Contents for D-Link DGS-1210/ME Series

  • Page 1: Hardware Installation Guide

    Hardware Installation Guide DGS-1210/ME Series Product Model : Metro Ethernet Switches Release 2.11 ©Copyright 2016. All rights reserved.
  • Page 2 Reproduction in any manner whatsoever without the written permission of D-Link Computer Corporation is strictly forbidden. Trademarks used in this text: D-Link and the D-Link logo are trademarks of D-Link Computer Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
  • Page 3: Table Of Contents

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Table of Contents Table of Contents ............................. i Intended Readers ............................. 1 Typographical Conventions ........................... 1 Notes and Cautions ............................1 Safety Instructions ............................1 Safety Cautions ............................1 General Precautions for Rack-Mountable ....................2 Protecting Against Electrostatic Discharge ....................
  • Page 4: Intended Readers

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Intended Readers The DGS-1210/ME Series Hardware Installation Guide contains information for set up and management of the Switch. This manual is intended for network managers familiar with network management concepts and terminology. For all practical reasons all the switches in this series will be simply referred to as the Switch throughout this manual.
  • Page 5: General Precautions For Rack-Mountable

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide bolt may expose the user to electrical shock. Only a trained service technician should service components inside these compartments. If any of the following conditions occur, unplug the product from the electrical outlet and replace •...
  • Page 6: Protecting Against Electrostatic Discharge

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide well as to various peripherals or supporting hardware. CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances.
  • Page 7: Product Introduction

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Product Introduction  Switch Description  Front Panel Description  LED Indicators  Rear Panel Description  Side Panel Description  Gigabit Fiber Port  Connecting the DPS-200A/500A/500DC to the RPS Port (for DGS-1210-10/12TS/20/28/28X/28XS/52/ME only) ...
  • Page 8 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide • LEDs for Power, PoE Max, Console, Link/Act for port 1 ~ 10 • Mode: By pressing the Mode button, the Port LED will switch between Link/Act and PoE modes. Figure 1.2 – DGS-1210-10P/ME Front Panel CAUTION: The MiniGBIC ports should use UL listed Optical Transceiver product, Rated Laser Class I.
  • Page 9 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide • One RJ-45 Console Port • LEDs for Power, RPS, Console, Link/Act for port 1 ~ 28 Figure 1.5 – DGS-1210-28/ME Front Panel CAUTION: The MiniGBIC ports should use UL listed Optical Transceiver product, Rated Laser Class I. 3.3Vdc.
  • Page 10 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide • LEDs for RPS, Power, Console, Fan Error, Link/Act for port 1 ~ 28 Figure 1.8 – DGS-1210-28X/ME Front Panel CAUTION: The MiniGBIC ports should use UL listed Optical Transceiver product, Rated Laser Class I. 3.3Vdc.
  • Page 11: Led Indicators

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide CAUTION: The MiniGBIC ports should use UL listed Optical Transceiver product, Rated Laser Class I. 3.3Vdc. NOTE: The power budget is 193 Watts for DGS-1210-52P/ME. The front panel of the DGS-1210-52MP/ME switch consists out of the following: •...
  • Page 12 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Location LED Indicative Color Status Description Solid Light Power on. Power Green Light off Power off. Solid Light Console on. Console Green Blinking POST is in progress. Light off Console off. Fan Error...
  • Page 13: Rear Panel Description

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Solid Off No Power feeding. When there is a secure Solid 1000Mbps Ethernet connection Green (or link) at any of the ports. Green When there is reception or Blinking transmission (i.e. Activity—Act)
  • Page 14 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide DGS-1210-12TS/ME Figure 1.17- DGS-1210-12TS/ME Rear Panel DGS-1210-20/ME Figure 1.18 - DGS-1210-20/ME Rear Panel DGS-1210-28/ME Figure 1.19 - DGS-1210-28/ME Rear Panel DGS-1210-28P/ME Figure 1.20 -DGS-1210-28P/ME Rear Panel DGS-1210-28MP/ME Figure 1.21 -DGS-1210-28MP/ME Rear Panel DGS-1210-28X/ME Figure 1.22-...
  • Page 15: Side Panel Description

    Figure 1.28 - Side panels of the DGS-1210/ME SERIES Gigabit Fiber Ports The DGS-1210/ME Series features support four Small Form Factor Portable (SFP) ports (optional). See the diagram below to view the four SFP port modules being plugged into the Switch.
  • Page 16: Connecting The Dps-200A/500A/500Dc To The Rps Port (For Dgs-1210-10/12Ts/20/28/28X/28Xs/52/Me Only)

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Figure 1.29 - Inserting the SFP modules into the Switch Figure 1.30- Installing the SFP Module The Switch is equipped with SFP ports, which are to be used with fiber-optical transceiver cabling in order to uplink various other networking devices for a gigabit link that may span great distances.
  • Page 17: Installing The Rps Into A Rack-Mount Chassis (For Dgs-1210-10/12Ts/20/28/28X/28Xs/52/Me Only)

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide The following section explains how to connect the DPS-200A/500A/500DC to the Switch. • Disconnect the Switch from the main AC power source. • Insert the 14-pin end of the DPS-CB150-2PS into the DPS-200A/500A/500DC and the 2-pin end into the receptacle of the RPS port on the Switch.
  • Page 18: Installation

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Installation This chapter provides unpacking and installation information for the D-Link Metro Ethernet Switch. Step 1: Package Contents Open the shipping carton and carefully unpack its contents. Please consult the packing list located in the User Manual to make sure all items are present and undamaged.
  • Page 19: Step 3 - Plugging In The Ac Power Cord

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Then, use the screws provided with the equipment rack to mount the switch in the rack. Figure 2.3 – Mount the Switch in the rack or chassis Please be aware of following safety Instructions when installing: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
  • Page 20: Power Failure

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Figure 2.4 – Plugging the switch into an outlet Power Failure As a precaution, the switch should be unplugged in case of power failure. When power is resumed, plug the switch back in.
  • Page 21: Switch Management

    Connecting to the Console Port Management Options The D-Link Metro Ethernet Switch can be managed through any port on the device by using the Web-based Management or command line interface. Each switch must be assigned its own IP Address, which is used for communication with the Web-Based Management or a SNMP network manager.
  • Page 22: Login Web-Based Management

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Login Web-based Management In order to login and configure the switch via an Ethernet connection, the PC must have an IP address in the same subnet as the switch. For example, if the switch has an IP address of 10.90.90.90, the PC should have an IP address of 10.x.y.z (where x/y is a number between 0 ~ 254 and z is a number between 1 ~ 254), and...
  • Page 23: Password Protection

    Figure 3.4 Initial Console Screen after Logging In Password Protection The DGS-1210/ME Series Switches do not have a password. One of the first tasks when settings up the Switch is to create user accounts. Logging in using a predefined administrator-level user name will give the user privileged access to the Switch's management software.
  • Page 24: Assigning Ip Addresses

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Assigning IP Addresses Each Switch must be assigned its own IP Address, which is used for communication with an SNMP network manager or other TCP/IP application (for example BOOTP, TFTP). The Switch's default IP address is 10.90.90.90.
  • Page 25: Snmp Settings

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide The IP address may be set using the Command Line Interface (CLI) over the console serial port as follows: Starting at the command line prompt, enter the commands config ipif System ipaddress xxx.xxx.xxx.xxx/yyy.yyy.yyy.yyy...
  • Page 26: Traps

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide describes what each user on that list can do as an SNMP manager. The Switch allows groups of users to be listed and configured with a shared set of privileges. The SNMP version may also be set for a listed group of SNMP managers.
  • Page 27: Web-Based Switch Configuration

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Web-based Switch Configuration  Logging onto the Web Manager  Web-based User Interface  Areas of the User Interface  Web Pages Logging onto the Web Manager In order to login and configure the switch via an Ethernet connection, the PC must have an IP address in the same subnet as the switch.
  • Page 28: Web Pages

    This area displays the Switch's ports and expansion modules and shows port Tool Bar activity, depending on the specified mode. Some management functions, including port monitoring are accessible here. Click the D-Link logo to go to the D-Link Website. Main...
  • Page 29 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide PoE – In this section the user will be able to configure features regarding the Power over Ethernet functionality of the Switch. Time-Based PoE – In this section the user will be able to configure features regarding the Time- •...
  • Page 30: Appendix A - Ethernet Technology

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Appendix A – Ethernet Technology The appendix contains the device specifications, and contains the topics: • Technical Specifications • Supported Transceivers Technical Specifications Performance Transmission Method Store-and-forward Switching Capacity DGS-1210-10/ME: 20Gbps DGS-1210-10P/ME: 20Gbps...
  • Page 31 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Performance DGS-1210-52MPP/ME: 77.4 Mpps MAC Address Learning Automatic update. Supports 16K MAC address. DRAM 256 MB – DDR3 Flash Memory 32 MB – SPI flash Priority Queues 8 Priority Queues per port.
  • Page 32 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Physical and Environmental Power Consumption DGS-1210-10/ME: Maximum power consumption: 13.59Watts Standby power consumption: 9.4Watts DGS-1210-10P/ME: Maximum power consumption: 103.4Watts (PoE on), 17.9Watts (PoE off) Standby power consumption: 11.1Watts DGS-1210-12TS/ME: Maximum power consumption: 13.85Watts Standby power consumption: 7.49Watts...
  • Page 33 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Physical and Environmental Maximum power consumption: 479.5Watts (PoE on), 54.4Watts (PoE off) Standby power consumption: 33Watts DGS-1210-52MPP/ME: Maximum power consumption: 957.9Watts (PoE on), 56.8Watts (PoE off) Standby power consumption: 37.8Watts Fans DGS-1210-10/ME: Fanless...
  • Page 34 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Physical and Environmental CE (DGS-1210-28X/ME, 28XS/ME only) Safety UL, CB, LVD, BSMI UL, CB, LVD (DGS-1210-28X/ME, 28XS/ME only) General Number of Ports: DGS-1210-10/ME: 8-Ports 10/100/1000Mbps + 2-Ports 1000Mbps SFP DGS-1210-10P/ME: 8-Ports PoE 10/100/1000Mbps + 2-Ports 1000Mbps SFP...
  • Page 35 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Standards • IEEE 802.3 10BASE-T Ethernet • IEEE 802.3u 100BASE-TX Fast Ethernet • IEEE 802.3ab 1000BASE-T Gigabit Ethernet • IEEE 802.3ae 10 Gigabit Ethernet (for 28X/ME, 28XS/ME) • IEEE 802.3u 100BASE-FX (for 28XS/ME) •...
  • Page 36 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Optional SFP Transceivers DEM-315GT 1000BASE-ZX, Single-mode, 80 km DGS-712 1000BASE-T 100 m (only supports 1000 Mbps mode) (no flow control) DEM-302S-LX 1000BASE-LX, Single-mode, 2 km DEM-210 100BASE-FX, Single-mode, 15 km (for DGS-1210-28XS/ME only)
  • Page 37: Appendix B - Cables And Connectors

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Appendix B – Cables and Connectors Ethernet Cable: When connecting the Switch to another switch, a bridge or hub, a normal cable is necessary. Please review these products for matching cable pin assignment.
  • Page 38 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Not Used GND (shared) Not Used Not Used Not Used Not Used Not Used...
  • Page 39: Appendix C - Module Specs And Cable Lengths

    DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide Appendix C – Module Specs and Cable Lengths Use the following table to as a guide for the module specs and maximum cable lengths. Maximum Standard Media Type Distance 1000BASE-T Category 5e UTP Cable...
  • Page 40 DGS-1210/ME series Metro Ethernet Switch Hardware Installation Guide 10GBASE-ZR (without DDM) (for DGS-1210- 80 km DEM-434XT 28XS/ME only) 10GBASE-LR BiDi (without DDM), TX-1330/RX-1270 20 km DEM-436XT-BXD nm (for DGS-1210-28XS/ME only) 10GBASE-LR BiDi (without DDM), TX-1270/Rx-1330 20 km DEM-436XT-BXU nm (for DGS-1210-28XS/ME only)
  • Page 41 Europe customers TECHNICAL SUPPORT TECHNISCHE UNTERSTÜTZUNG ASSISTANCE TECHNIQUE ASISTENCIA TÉCNICA SUPPORTO TECNICO TECHNISCHE ONDERSTEUNING POMOC TECHNICZNA TECHNICKÁ PODPORA TECHNICKÁ PODPORA dlink.com/support TECHNIKAI TÁMOGATÁS TEKNISK SUPPORT TEKNISK SUPPORT TEKNISK STØTTE TEKNINEN TUKI ASSISTÊNCIA TÉCNICA ΤΕΧΝΙΚΉ ΥΠΟΣΤΉΡΙΞΗ TEHNIČKA PODRŠKA TEHNIČNA PODPORA SUPORT TEHNIC ТЕХНИЧЕСКА...
  • Page 42 Indonesia - www.dlink.co.id Malaysia - www.dlink.com.my Philippines - www.dlink.com.ph Vietnam - www.dlink.com.vn Korea customers Tel : +82-2-2028-1810 Monday to Friday 9:00am to 6:00pm Web : http://d-link.co.kr E-mail : g2b@d-link.co.kr New Zealand customers Tel: 0800-900-900 24/7 Technical Support Web: http://www.dlink.co.nz E-mail: support@dlink.co.nz...
  • Page 43 08600 DLINK (for South Africa only) Monday to Friday 8:30am to 9:00pm South Africa Time Web: http://www.d-link.co.za E-mail: support@d-link.co.za D-Link Middle East - Dubai, U.A.E. customers Plot No. S31102, Jebel Ali Free Zone South, P.O.Box 18224, Dubai, U.A.E. Tel: +971-4-8809022...
  • Page 44 Pakistan customers Islamabad Office: 61-A, Jinnah Avenue, Blue Area, Suite # 11, EBC, Saudi Pak Tower, Islamabad - Pakistan Tel.: +92-51-2800397, 2800398 Fax: +92-51-2800399 Karachi Office: D-147/1, KDA Scheme # 1, Opposite Mudassir Park, Karsaz Road, Karachi – Pakistan Phone: +92-21-34548158, 34326649 Fax: +92-21-4375727 Technical Support: +92-21-34548310, 34305069 General Inquiries: info.pk@dlinkmea.com...
  • Page 45 Lebanon RMA center customers Dbayeh/Lebanon PO Box:901589 Tel: +961 4 54 49 71 Ext:14 Fax: +961 4 54 49 71 Ext:12 Email: taoun@dlinkmea.com Bahrain customers Technical Support: +973 1 3332904 Kuwait customers Technical Support: + 965 22453939 / +965 22453949...
  • Page 46 Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link. D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока. Клиенты могут обратиться в группу технической поддержки D-Link по телефону или через Интернет. Техническая поддержка компании D-Link работает в круглосуточном режиме ежедневно, кроме официальных праздничных дней. Звонок...
  • Page 47 Tel: +373 (22) 80-81-07 E-mail:info@dlink.md Беларусь Мінск, пр-т Незалежнасці, 169 Тэл.: +375 (17) 218-13-65 E-mail: support@dlink.by Қазақстан Алматы, Құрманғазы к-cі,143 үй Тел.: +7 (727) 378-55-90 E-mail: almaty@dlink.ru Հայաստան Երևան, Դավթաշեն 3-րդ թաղամաս, 23/5 Հեռ.՝ +374 (10) 39-86-67 Էլ. փոստ՝ info@dlink.am Latvija Rīga, Lielirbes iela 27 Tel.: +371 (6) 761-87-03...
  • Page 48 Soporte Técnico Para Usuarios En Latino America Por favor revise el número telefónico del Call Center de su país en http://www.dlinkla.com/soporte/call-center Soporte Técnico de D-Link a través de Internet Horario de atención Soporte Técnico en www.dlinkla.com e-mail: soporte@dlinkla.com & consultas@dlinkla.com...
  • Page 49 Clientes de Brasil Caso tenha dúvidas na instalação do produto, entre em contato com o Suporte Técnico D-Link. Acesse o site: www.dlink.com.br/suporte...
  • Page 50 香港技術諮詢服務專線 (852) 8100 8892 香港服務時間: 週一至週五: 10:00 ~ 19:00 週六: 09:00~13:00 / 週日及公眾假期休息 香港網站: http://www.dlink.com.hk 香港電子郵件: service@cn.synnex-grp.com 香港地區維修據點如下: 維修據點: 葵芳服務中心地址:新界葵涌大連排道 202-210 號偉倫中心一期 1 樓 A 室 灣仔服務中心地址:香港灣仔莊士敦道 178 號 -188 號華懋莊士敦廣場 16 樓 02 室 如果您是其他地區的用戶,請參考 D-Link 網站 www.dlink.com 查詢全球各地分 公司的聯絡資訊以取得相關支援服務。...
  • Page 51 Pelanggan Indonesia Update perangkat lunak dan dokumentasi pengguna dapat diperoleh pada situs web D-Link. Dukungan Teknis untuk pelanggan: Tel: 0800-14014-97 (TOLL FREE) Dukungan Teknis D-Link melalui Internet: Email : support@id.dlink.com Website : http://www.dlink.co.id 日本のお客様 この度は弊社製品をお買い上げいただき、誠にありがとうございます。 製品に同梱されている保証書の購入元にお問い合わせください。 中國客戶 技術支持中心電話: 400-629-6688 技術支持中心郵箱: dlink400@cn.dlink.com 各地維修中心地址請登錄官方網站查詢...
  • Page 52: Registration Card

    8. What category best describes your company? Aerospace Engineering Education Finance Hospital Legal Insurance/Real Estate Manufacturing Retail/Chain store/Wholesale Government Transportation/Utilities/Communication System house/company Other________________________________ 9. Would you recommend your D-Link product to a friend? Don't know yet 10.Your comments on this product? __________________________________________________________________________________________ __________________________________________________________________________________________...

Table of Contents