BEFORE USING THE APPLIANCE
To make the most out of your new appliance,
please read the user instructions carefully and keep
them handy for future consultation.
Before using the appliance please follow and
set according to the below indications:
Remote Control (RC) presetting:
Each time the batteries are replaced in the remote
control, the RC is pre-set on Heat pump.
If the air conditioner that you purchased is a
cooling only, then the pre-set on Heat pump will
not bring any changes.

SAFETY PRECAUTIONS

• Do not install the appliance if it is connected to
the power supply.
• The Installation and service/repair must be
performed by a qualified technician, in
compliance with the producer's instructions and
following local safety norms. Do not repair or
replace any parts of the appliance unless it is
specifically written in the user instructions.
• The grounding of this appliance is compulsory.
• Make sure that the power supply cord is long
enough to allow the right connection. Do not
use any extension cord for power supply.
• Do not pull the power supply cord to remove it
from the socket.
• Do not twist or press the power supply cord,
and make sure it is not broken.
Downloaded from AC-Manual.com Manuals
Auto-Restart presetting Function:
To set the auto-restart function, press the
Emergency button (ON/OFF) on the indoor unit
for at least 5 seconds
A buzz sound will signal that the auto-restart
function is set and the air conditioner is in standby.
To cancel the auto-restart function, repeat the
above steps.
• Once installation is completed, the electric
components must not be accessible to the users.
• Do not touch the operation buttons when your
hands are wet and don't use the appliance when
you are barefoot.
• Physically or mentally disabled people, children
and people without any experience with the
product are only allowed to use the appliance if
they have had specific training on how to
operate the appliance by a person responsible
for their security and well-being. The appliance
is not intended for use by disabled people and
very young children without supervision.
4

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool AMD 302

  • Page 1: Safety Precautions

    BEFORE USING THE APPLIANCE To make the most out of your new appliance, Auto-Restart presetting Function: please read the user instructions carefully and keep To set the auto-restart function, press the them handy for future consultation. Emergency button (ON/OFF) on the indoor unit for at least 5 seconds Before using the appliance please follow and A buzz sound will signal that the auto-restart...
  • Page 2: Safeguarding The Environment

    AIR CONDITIONER PRECAUTIONS Please strictly follow the below instructions: • Do not place any objects on the outdoor unit. • Long and direct exposure to cool air might be • This product contains Fluorinated Greenhouse harmful to health. It is advisable to set the Gases covered by the Kyoto Protocol, the louvers in order to avoid direct cool air and refrigerant gas being in a hermetically sealed...
  • Page 3: Identification Of Parts

    IDENTIFICATION OF PARTS 1. Outdoor unit and Indoor unit 1. Filter 2. Front Panel 3. Air inlet 4. Display 5. Deflector 6. Left / Right deflector (Manual operation) Outdoor unit 7. Air inlet 8. Connecting pipe 9. Drain hose 10. Air outlet 11.
  • Page 4 The following table shows the set temperature, fan speed and deflector values during emergency operation. Mode Set temperature Fan speed Deflector Cooling 24 °C High Swing Heating 24 °C High Swing Hold the knob and move the deflector to change right/left airflow direction. Never attempt to adjust the deflector during operation as the fan rotates at very high speed and may injure your fingers.
  • Page 5 STORAGE AND TIPS FOR USING THE RC How to Insert the Batteries Remove the battery cover in the direction of the arrow. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Refit the cover by sliding it back into position. Note: •...
  • Page 6: Operating Mode Description

    OPERATING MODE DESCRIPTION AUTO restart • The same mode/ fan speed/set temperature/swing angle as prior to the power cut are restored. COOL mode • Press SWING button to change up/down air flow direction. Press FAN button to change the fan speed of the indoor unit. Press the TEMPERATURE ADJUSTMENT button to change the temperature setting.
  • Page 7 6TH SENSE mode Used to enter fuzzy logic operation directly. Mode Initial room temperature .A Initial room temperature .B RT ≥ 26°C 24°C Cooling 26°C >RT ≥ 25°C RT-2 25°C >RT ≥ 23°C RT-2 Heating RT < 23°C 26°C Timer operation Preparation Before Operation •...
  • Page 8: Service And Maintenance

    SERVICE AND MAINTENANCE Clean the front grille and air filters at least once every two weeks. Before cleaning, be sure to switch the appliance off and turn off the circuit breaker. In this section, diagrams are for illustration purposes only. During operation, please refer to your actual appliance.
  • Page 9: Troubleshooting

    TROUBLESHOOTING Operation problems are often due to minor causes that can be found and fixed without using any tools: Trouble Analysis • Is the protection device or fuse blown? • Please wait for 3 minutes and start again, protection device may be Does not run preventing unit to work.
  • Page 10: Notice D'installation

    NOTICE D’INSTALLATION Confirm the installation position using the marks on the indoor mounting plate. Note: Different models have different mounting plates, the installing charts of this book are presented just for the purpose of illustration, please take the real objects as reference.
  • Page 11: Installation Of The Indoor Unit

    Location of indoor unit • Keep the air inlet and outlet at a far distance from the blockage. • Keep the difference in height between the indoor and outdoor unit to 5m max. • Mount on a wall that is solid enough to bear the weight of the unit and not cause any shaking. •...
  • Page 12: Installation Of The Drain Hose

    NOTE: • The appliance must be installed in accordance with national wiring regulations. • The appliance must not be installed in a laundry area. • The appliance must be installed at a height of 2.3m above the floor. • The appliance must be positioned so that the plug is accessible. •...
  • Page 13: Pipe Connection

    Pipe Connection • The number of bends in the pipe in the indoor unit must evaporator not exceed 10. craft tube • The number of bends in the pipe in the indoor unit and outdoor unit taken together must not exceed 15. •...
  • Page 14: Installation Of The Outdoor Unit

    INSTALLATION OF THE OUTDOOR UNIT Wiring Wiring For Above 6000W Model (Above 21000BTU/h Model) 1. Remove the self-tapping screws (2 pcs) on the maintenance board and take out the maintenance board. 2. Loosen the self-tapping screws (2 pcs) on the fixing Outdoor unit terminal clip to loosen the fixing clip.
  • Page 15: Connect Diagram

    Connect diagram 1500-4600W Model (5000-12000BTU/h Model) Indoor unit terminal Plug housing 1 Plug housing 1 Indoor unit terminal Connecting cable Brown Black Connecting Brown Yellow/Green Blue cable Brown Gray Blue Blue Brown Gray Blue Yellow/Green Brown Yellow/Green Plug housing 2 Black Blue Outdoor unit terminal...
  • Page 16 MODEL SPECS (Interconnection cable) ≤ 2700W(10000BTU/h) ≥ 1.0mm² ≥ 1.5mm² 3200W(11000BTU/h) - 4000W(15000BTU/h) ≥ 2.5mm² 4500W(16000BTU/h) - 8000W(28000BTU/h) ≥ 4.0mm² 8500W(29000BTU/h) - 9500W(32000BTU/h) ≥ 6.0mm² 10000W(34000BTU/h) - 11000W(38000BTU/h) WARNING: • The electric circuit diagram given on the indoor/outdoor units must be taken as the main reference for installation.
  • Page 17: Adding Refrigerant

    Expelling air • Screw down the cap of both the gas shut-off valve liquid and the liquid shut-off valve as well as the nut of the connecting pipe service port. • Use an Allen wrench to turn the liquid shut-off valve liquid shut-off valve allen wrench 90°...
  • Page 18 • Expel the air following the above-mentioned method. Pressure meter Manifold gauge • Close the gas shut-off valve, connect the charging High pressure valve Low pressure valve hose (low pressure) to the service valve and then open the gas shut-off valve again. •...