Chapter 8
Code*
E194-4034
8.3 Sevice Call Table
8.3.1 Service Call Errors
iPF5000 / iPF5100
*Codes correspond to the numbers shown on the DIPLAY in the service mode.
E141-4046
E144-4047
E146-4001
E161-403E
E196-4034
E194-404A
E196-403F
E196-4040
E196-4041
E196-4042
E196-4045
E196-404C
8-4
Sensor calibration error(not generated in the user mode.)
Code*
Condition detected
Number of recovery rotations reaching
50,000 or more
Supply count error
Borderless/flow idle ejection/mist recovery
counter full
Abnormal temperature rise in printhead R Replace the printhead.
Multi sensor unit version error
Non-discharging nozzle count error
Abnormal temperature rise printhead L
Checksum error
Flash memory erase error
Flash memory write error
EEPROM write error
Serial number mismatch between boards
Description
T-8-3
Action
Replace the purge kit.
Replace the ink supply unit.
Replace the platen duct unit.
Replace the multi sensor unit
Replace the head management sensor unit
Replace the printhead
Replace the main controller PCB
Replace the main controller PCB
Replace the main controller PCB
Replace the main controller PCB
Retry PCB replacement mode.
0012-8350