Simeas-t series with auxiliary power for alternating voltage or alternating current rms with expanded start/end range and non-linear characteristic curve
Table of Contents

Advertisement

SIMEAS-T - Transducer with auxiliary power
Test circuit for voltage and current transducers
(example for current output).
1 Alternating voltage encoder (THD ≤ 1%) 0 to 600 V or
Alternating current encoder (THD ≤ 1%) range 0 to 10 A
2 Voltmeter, class 0.01 (for voltage input)
3 Ammeter, class 0.01, Ri ≤ 0.1 Ω (for current input)
4 Test specimen, voltage or current transducer
5 Decade resistor 0 to 20 kΩ
6 Ammeter, class 0.01, Ri ≤ 10 Ω
7 Alternating and direct voltage encoder
8 Voltmeter