Hitachi FLASHMAX2 User Manual page 47

Pcie flash drive
Table of Contents

Advertisement

After Disk Management is selected, the Initialize Disk dialog box may appear.
In this case, select MBR (Maser Boot Record) or GPT (GUID Partition
Table) and then click OK. If you want to create a memory of 2 TB or more,
you need to select GPT. If you are using a Flash Drive with memory more than
2 TB (2.2 TB or 4.8 TB), select GPT.
[RAID0 (striping) Replacing a faulty drive]
1. Turn off the system.
2. Replace the faulty Flash Drive with a new one.
3. Turn on the system.
4. From the Start menu, select Administrative Tools, Computer, Memory,
and Disk Management. Right-click the "failed" area to the right of the faulty
disk, and then select Delete Volume.
5. When the Delete Striped Volume dialog box appears, click Yes.
6. Restart the system.
7. Configure the RAID again as described in
For Windows Server 2012 R2
on
page 3-25.