3Way Valve - LG ARNH08GK3A2 Installation Manual

Hydro kit
Hide thumbs Also See for ARNH08GK3A2:
Table of Contents

Advertisement

Accessories Installation

3Way Valve

3way valve is required to operate sanitary water tank. Role of 3way valve is flow switching between
under floor heating loop and water tank heating loop.
General Information
Hydro Kit supports following 3way valve.
Type
SPDT
3-wire (1)
(1) SPDT = Single Pole Double Throw. Three wires consist of Live (for selecting Flow A), Live 1 (for
selecting Flow B), and Neutral (for common).
(2) Flow A means ʻwater flow from the unit to sanitary water tankʼ
(3) Flow B means ʻwater flow from the unit to under floor water circuitʼ
How to Wire 3Way Valve
Follow below procedures Step 1 ~ Step 2.
Step 1. Uncover front cover of the unit and open the control box.
Step 2. Find terminal block and connect wire as below.
3WAY VALVE
(A)
4
5
6
L
L1
N
BR
WH
BL
(W)
(U)
3way valve
(W) : Live signal (Water tank heating) from PCB to 3way valve
(U) : Live signal (Under floor heating) from PCB to 3way valve
(N) : Neutral signal from PCB to 3way valve
WARNING :
Mice can not be appeared to prevent entering the unit or attacking wires.
30 Hydro Kit
Power
1~ 230 V
WARNING :
• 3way valve should select water tank loop when electric power is
supplied to wire (W) and wire (N).
• 3way valve should select under floor loop when electric power is
(N)
supplied to wire (U) and wire (N).
Operating Mode
Selecting "Flow A" between
"Flow A" and "Flow B" (2)
Selecting "Flow B" between
"Flow A" and "Flow B" (3)
Supported
Yes
Yes

Hide quick links: