Problems; Problem/Cause/Solution - Bosch Tronic 1000T ES 30 User And Installation Manual

Electrical storage water tank tronic 1000t series; tronic 2000t
Hide thumbs Also See for Tronic 1000T ES 30:
Table of Contents

Advertisement

9

Problems

9.1

Problem/Cause/Solution

DANGER:
Assembly, maintenance and repairs should
only be carried out by authorized
technicians.
Problem
X
X
X
X
X
X
X
X
X
X
X
X
X
Table 13
Tronic 1000T / 2000T
Cause
Plant or circuit breaker surcharge
(capacity exceeded).
Incorrect temperature regulating through
the thermostat.
Thermostat temperature safety active.
Damaged heating element.
Incorrect functioning of the thermostat
Device incrustation and / or from the
safety group.
X
Hydraulic system pressure.
X
Hydraulic system capacity.
X
Appliance corrosion.
X
Bacteria development.
Device incorrectly dimensioned for the
consumption.
In the following diagram there are some solutions described for
possible problems / troubleshooting (these should only be
performed by authorized technicians).
Solution
▶ Verify if the device is connected to a
dedicated electric point to supply
sufficient electric current to the
device.
▶ Regulate the thermostat.
▶ Replace or re-install the thermostat.
▶ Replace the heating element.
▶ Replace or re-install the thermostat.
▶ Perform a descaling of the appliance.
▶ If necessary replace the safety group.
▶ Verify the system pressure.
▶ If necessary install a pressure
reducing valve.
▶ Verify the piping.
▶ Drain the appliance and check for
interior corrosion.
▶ Replace the magnesium anode.
▶ Drain, clean the device.
▶ Disinfect the appliance.
▶ Replace by another, following the
consumption.