Mode=4, Programming Mode - ABB 83327-500 Product Manual

Welcome camera interface
Hide thumbs Also See for 83327-500:
Table of Contents

Advertisement

ABB-Welcome
4.2.4

Mode=4, programming mode

Fig. 5:
mode=4, programming mode
Rotary
Value
Mode
4
Addr
null
ID
null
Dip Switch 1-4
Capacity
Each camera interface supports 4 analog cameras. Each camera can be associated with
different devices (i.e., outdoor station, guard unit, video indoor station).
A total of 36 cameras can be associated with each video indoor station. Each camera can be
associated with 250 indoor stations.
|
Note
Camera interface works in programming mode.
Camera interface mode, camera interface address and associated device
address can all be programmed with software.
In mode=4, besides camera interface and guard unit, camera interface
can also be associated with video indoor station.
If camera interface is associated with video indoor station, ID should start
from 1 to 9 sequently.
For details, see
Chapter 4.3 Programming mode.
Turn to ON when a camera is connected.
— 9 —