Error
code
7
H
8
H
F01
F02
Technology Module TM PTO 4 (6ES7553-1AA00-0AB0)
Manual, 12/2016, A5E38896703-AA
Name
Read measuring input
value aborted
Absolute value acquisi-
tion aborted
Command not support-
H
ed
Sign-of-life error (Mas-
H
ter Sign-Of-Life)
Meaning
G1_XIST2 does not contain a valid value of the measuring
•
input.
The Mode bit was set to 0 while the measuring input value
•
was being read from G1_XIST2.
CPU STOP while the measuring input value was being read
•
from G1_XIST2.
The Request_Absolute_value_Cyclically bit is not supported by
the module. The module returns only incremental encoder values.
The command is not supported by the module.
The number of tolerated errors of the Master sign-of-life (control
value Master_Sign-Of-Life) was exceeded.
Configuring/address space
4.5 Control and feedback interface