Mitsubishi Electric FX3G-14M series Hardware Manual page 8

Melsec-f fx3g series
Hide thumbs Also See for FX3G-14M series:
Table of Contents

Advertisement

3.7
Triac output specifications and example of
external wiring
As for the details of the triac output specifications and external
wiring, refer to the following manual.
→ Refer to FX
Series User's Manual - Hardware Edition.
3G
3.7.1
Triac output specifications
Item
Specification
Number
FX
-16EYS,
2N
of output
16 points
FX
-32ES
2N
points
Refer to FX
Series
3G
Output connecting type
User's Manual - Hardware
Edition
Output form
Triac (SSR)
External power supply
85 to 242V AC
*
0.3A/point(
1)
Resistance load
Max. load
15VA/100V AC,
Inductive load
30VA/200V AC
0.4VA/100V AC,
Min. load
1.6VA/200V AC
1mA/100V AC,
Open circuit leakage current
2mA/200V AC
OFF→ON
1ms or less
Response
time
ON→OFF
10ms or less
Circuit insulation
Photo-thyristor insulation
LED on panel lights when
Display of output operation
photo-thyristor is driven.
*
(
1) The total load current of resistance loads per common
terminal should be the following value or less.
- 4 output points/common terminal : 0.8A
- 8 output points/common terminal : 0.8A
As for the number of outputs per common terminal, refer to
"Chapter 4 interpretation of partition" and the following manual.
→ Refer to FX
Series User's Manual - Hardware Edition.
3G
3.7.2
External Wiring of Triac Output
Load
Y0
AC power
Fuse
supply
U
COM1
Load
Y4
AC power
Fuse
supply
U
COM2
PLC
3.7.3
Cautions in external wiring
As for the details of Instructions for connecting input devices, refer to
the following manual.
→ Refer to FX
Series User's Manual - Hardware Edition.
3G
Protection circuit for load short-circuits
A short-circuit at a load connected to an output terminal could cause
burnout at the output element or the PCB. To prevent this, a
protection fuse should be inserted at the output.
Micro current load
The PLC's internal Triac output circuit is equipped with a turn-off C-R
absorber. When connecting a very low current load of "0.4VA/100V
AC or less, or 1.6VA/200V AC or less", please connect a surge
absorber parallel to the load.
Select the rated voltage of a surge absorber that is suitable for the
load being used. Refer to the table below for other specifications.
Item
Guide
Static electricity capacity Approx. 0.1μF
Resistance value
Approx. 100 to 200Ω
Interlock
Loads, such as contactors for normal and reverse rotations, that
must not be turned on simultaneously should have an interlock in the
PLC program and an external interlock.
4.
Terminal block layouts
For details on the terminal block layout, refer to the following manual.
→ Refer to FX
Series User's Manual - Hardware Edition.
3G
Interpretation of partition
The partition of the output terminals (see following figure) indicates
the range of the output connected to the same common.
Example: FX
-40MT/ES
3G
Output terminal
0V
Y0
Y1
24V
COM0 COM1
Partition
「电器电子产品有害物质限制使用标识要求」 的
表示方式
Note: This symbol mark is for
China only.
含有有害6物质的名称, 含有量, 含有部品
 本产品中所含有的有害6 物质的名称, 含有
量, 含有部品如下表所示。
产品中有害物质的名称及含量
有害物质
部件名称
六价铬
(Pb)
(Hg)
(Cd)
(Cr(VI))
外壳
可编程
控制器
印刷基板 ×
有害物质
部件名称
多溴联苯
多溴二苯醚
(PBB)
(PBDE)
外壳
可编程
控制器
印刷基板
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中
的含量均在GB/T 26572规定的限量要求以
下。
×:表示该有害物质至少在该部件的某一均质
材料中的含量超出GB/T 26572规定的限量
要求。
This manual confers no industrial property rights or any rights of any
other kind, nor does it confer any patent licenses. Mitsubishi Electric
Corporation cannot be held responsible for any problems involving
industrial property rights which may occur as a result of using the
contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for
compensation to:
(1) Damages caused by any cause found not to be the responsibility
of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of
Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable
or not, compensation for accidents, and compensation for damages
to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up
test run and other tasks.
For safe use
This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi Electric.
This product has been manufactured under strict quality control.
However when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI,
CHIYODA-KU, TOKYO 100-8310, JAPAN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3g-40m seriesFx3g-60m seriesFx3g-24m series

Table of Contents