Outdoor Timer Installation
Preparing the Timer Cabinet
1.. Remove.the.lower.housing.cover.by.pulling.
outward.on.the.handle.
2.. Remove.two.phillips.screws.from.the.transformer.
access.cover..Pull.the.cover.outward.from.the.
bottom.to.remove..
Note:.Three.lower.mounting.holes.are.provided..
The.center.hole.is.open.and.the.outer.holes.
partially-through.pilot.holes..If.the.outer.holes.are.
to.be.used,.open.the.pilot.holes.using.a.3/16".
(6mm).drill.bit.
Three.wiring.(conduit).access.holes.are.provided.in.
the.cabinet.base.as.follows:
. 1. –.1/2" (13mm).for.input.power.wires.
. 1. –.3/4".(19mm).for.sprinkler.valve.wires.
. 1.–.1/2". (13mm).for.Toro.RainSensor.(optional)...
Note:.Leave.access.holes.plugged.if.not.used.
4
Installing the Cabinet
1.. For.safe,.reliable.operation,.select.an.installation.
site.which.will.provide.the.following.conditions:
. •.Protection.from.irrigation.spray,.exposure.to.
direct.sun.during.the.hottest.hours,.wind.and.
snow.
. •.Access.to.a.grounded.power.source.which.
is.not.controlled.by.a.light.switch.or.utilized.
by.a.high.current.load.appliance,.such.as.a.
refrigerator.or.air.conditioner.
. •.Access.to.the.sprinkler.control.valve.wiring.and.
optional.accessory.wiring.
2.. Drive.a.provided.stainless.steel.screw.into.the.
wall.at.eye.level..Leave.a.1/4".(6.4mm).gap.
between.the.screw.head.and.the.wall..
Note:.Use.appropriate.screw.anchors.if.installing.
the.timer.on.drywall.or.masonry.
3.. Hang.the.cabinet.on.the.screw.using.the.keyhole..
slot.on.the.back.panel..Make.sure.the.cabinet.
slides.down.securely.on.the.screw.
4.. Install.the.lower.mounting.screw(s).and.tighten.
securely.
.
Note:.Conduit.and.adapters.are.not.provided..
Install.conduit.as.required.by.electrical.code.