Battery Charging (Ign : Ignition) / Current Consumption - Philips CT5398 Service Manual

Hide thumbs Also See for CT5398:
Table of Contents

Advertisement

Depart. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
8.3

Battery Charging (IGN : Ignition) / Current consumption

8
.3.1
Charger detection / Battery charging
- Plug the transformer unit into an ea
- Insert the Test production
current measurement.
- Plug the connector of the charger (Basic Switch Mode Charger euro 2003 with Jack Connector +4.2V 0.30A max.)
into the right socket at the base of the transceiver. The battery symbol should indicate the state of charge :
Bars moving
Steady
If the battery is totally discharged, the battery icon will start scrolling 2 to 3 minutes only after being connected to
charger.
Just after charger plugging a pre-charge current 30 < I (mA) < 70 can be observed during 2 or 3 seconds
After few seconds a charge current of 180 mA approx. has to be observed
- Unplug the charger
 PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
sily accessible AC power socket.
Card in the mobile, plug a
+
BAT -
- means the battery is being charged.
- means the battery is fully charged.
dummy Battery with a multimeter ad
A
-
COMPANY RESTRICTED
VY-V-640-P530
Page : 26 of 64
Langue : EN
Date : 21/07/03
ded (see picture) for
BAT
VY-V-640-P530
+