Depart. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
8.3.2
Current consumption
a
) Check current_OFF :
When
th
e mobile is OFF the current measured
b) Check Current_ON
- Turn the mobile on.
When the mobile is ON (backlight activated) the current measured must be :
220 < I (mA) < 260
This measurement has
c
) Check Current_maximum
- Press on # to activate Page selection. Press the Key 1 and then OK to select Page 1
- Press on Key 7 to select Antenna test. Press on the Key 8 as much times as necessary to reach level 5. (T
m
obile is now set at his maximum emission level)
Wh
en
th
e mobile is emitting (backlight OFF) the current meas
- Remove the battery.
- Gently slide the card out away from the Product
PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
must be : 0.00 < I (mA) < 0.23
to be op
erated during first seconds after switch on.
COMPANY RESTRICTED
ured must be :
175 < I (mA) < 225
VY-V-640-P530
VY-V-640-P530
Page : 27 of 64
Langue : EN
Date : 21/07/03
he
(Typ. 195mA)