Frequent opening of
fuses or circuit
breakers.
BLADE TROUBLES AND SOLUTIONS
DISCONNECT POWER CORD TO MOTOR BEFORE ATTEMPTING ANY REPAIR OR INSPECTION.
TROUBLE
Too few teeth per inch
Loading of gullets
Teeth
strippage
Excessive feed
Work not secured in vise
Teeth too coarse
Misalignment of guides
Dry cutting
Excessive speed
Blade
breakage
Excessive speed
Excessive tension
Wheels out of line
Guides out of line
Excessive pressure
Blade line
Run-out or
Support of blade insufficient
Run-in
Material not properly secured
in vise
Blade tension improper
Blade not in line with guide
Blade
bearings
twisting
Excessive blade pressure
Motor overloaded
Motor overloaded
Incorrect fuses or circuit
breakers.
PROBABLE CAUSE
Reduce motor load.
Reduce motor load
Install correct fuses or circuit breakers.
SUGGESTED REMEDY
Use finer tooth blade
Use coarse tooth blade or cutting lubricant.
Decrease feed
Clamp material securely
Use a finer tooth blade
Adjust saw guides
Use cutting lubricant
Lower speed. See Operating Instructions "Speed
selection."
Reduce feed pressure. Refer to Operating Instructions
"Adjusting Feed."
Tension blade to prevent slippage on drive wheel while
cutting.
Adjust wheels
For a straight and true cut, realign guides, check
bearings for wear.
Conservative pressure assures long blade life and clean
straight cuts.
Move saw guides as close to work as possible.
Clamp material in vise, level and securely.
Loosen or tighten tension on blade.
Check bearings for wear and alignment.
Decrease pressure and blade tension