  • Page 1 Relion 605 series ® Self-powered feeder protection Relion 605 series ® Relion 605 series ® REJ603 Product Guide...
  • Page 2: Table Of Contents

    10. Local HMI ..............6 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document.
  • Page 3: Description

    REJ603 is a member of class and are based on ABB’s in-depth ABB’s Relion product family and part of its 605 knowledge of protection and numerical ®...
  • Page 4: Protection Functions

    ● = Included, o = Optional at the time of ordering Protection functions (LI) and IDMT characteristics as per ANSI REJ603 offers three-stage overcurrent and two- C37.112 Moderate inverse, Normal Inverse, Very stage earth-fault protection functions. The inverse, Extremely inverse. The...
  • Page 5: Application

    Issued: 2017-11-21 Revision: E Application The relay continuously measures thermal level. The REJ603 is a protection relay aimed at selective short-circuit and earth-fault protection Event log of feeders in secondary distribution networks and for protection of transformers in utilities and To collect sequence –...
  • Page 6: Access Control

    12. Application warning indication even in absence of primary CT In case the relay REJ603 (optional functionality current. with external power supply) is supplied with UPS step-wave or square-wave, an interposing...
  • Page 7: Technical Data

    Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E 13. Technical data Table 5. Dimensions Relay type Description Value frame 132.5 mm Width case 121.5 mm frame 167.0 mm Height case 137.0 mm Depth case 182.5 mm...
  • Page 8 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-011-21 Revision: E Table 8. Binary input (optional functionality with external power supply) Description Value 24...240 V AC, 50 and 60 Hz Rated voltage 24...240 V DC 85...110% of Uaux (20.4...264 V AC) Operating range 80...120% of Uaux (19.2...288 V DC)
  • Page 9 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E Table 12. Environmental conditions Description Value Operating temperature range -25...+55ºC -40...+85ºC (<16 h) Short-time service temperature range Display viewable range : above -20 ºC up to +70 ºC Relative humidity <...
  • Page 10 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-011-21 Revision: E Table 15. Electromagnetic compatibility tests, continued Description Type test value Reference Fast transient disturbance tests: IEC 60255-26, IEC 61000-4-4 4 kV, 5.0 kHz All ports  Not applicable for low energy trip...
  • Page 11 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E Table 16. Insulation tests Description Type test value Reference Dielectric test IEC 60255-27 2 kV, 50 Hz, 1 min  Test voltage 0.5 kV, 50 Hz, 1 min ...
  • Page 12 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-011-21 Revision: E Table 19. Product safety Description Type test value LV directive 2014/35/EU Standard EN 60255-27 (2014) EN 60255-1 (2010) Table 20. EMC compliance Description Type test value EMC directive...
  • Page 13: Protection Functions

    Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E 14. Protection functions Table 22. Low-set phase overcurrent protection, stage I> / 51 Parameter Value (Range) Setting range of pick-up current ‘I >’ ...32 x In in steps 0.001, infinite Operation accuracy ±...
  • Page 14 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-011-21 Revision: E Table 24. Very high-set phase overcurrent protection, stage I>>> / 50-2 Parameter Value (Range) Setting range of pick-up current ‘I >>>’ 0.2...32.0 x In in steps 0.001, infinite for CT variant Operation accuracy ±...
  • Page 15 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E Table 26. High- set earth-fault protection, stage I0>> / 50N Parameter Value (Range) Setting range of pick-up current ‘I0 >>’ External earth measurement (through CBCT or residual connection) : 0.01...12.5 x In in steps 0.001, infinite...
  • Page 16 80 ms minimum value of tripping time when switch-on to fault Figure 2: Switch-on to fault characteristics of relay REJ603 Note: 1. Operation time accuracy for protection functions shall be as indicated in Table 22-27 when relay is in energised condition.
  • Page 17: Dimensions And Mounting

    The REJ603 have been supplied with mounting With appropriate mounting accessories the clamps facilitating the easy flush mounting on REJ603 can also be mounted on the secondary the panel. circuit breakers and Ring Main Units. The panel cut-out for flush mounting: Height : 137.0 ±...
  • Page 18: Selection And Ordering Data

    None Ring lug terminals For future use Version Product version 3.0 With binary input =1, dual powered option = 4 needs to be selected Example order code: REJ603 B 1 N N 1 N B 3 4 N N J...
  • Page 19 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E Your ordering code: Digit (#) Code Figure 5. Ordering key for complete relay...
  • Page 20: Terminal Diagram

    Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-011-21 Revision: E 17. Terminal diagram Figure 6. Terminal diagram of REJ603 V3.0 with external earth connection through CBCT...
  • Page 21 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-11-21 Revision: E Figure 7. Terminal diagram of REJ603 V3.0 with external earth connection through residual connection...
  • Page 22 Self-powered feeder protection 1MDB07217-YN REJ603 Product version: 3.0 Issued: 2017-011-21 Revision: E Figure 8. Terminal diagram of REJ603 V3.0 with internal earth connection...
  • Page 23: References

    Web page helps you find the documents by the document category and You will find the latest relevant information on language. the REJ603 protection relay on the product page. The Features and Application tabs contain product related information in a compact format.
  • Page 24 Contact us ABB India Ltd, Distribution Automation Maneja Works Vadodara-390013, India Phone: +91 265 6724402 Fax: +91 265 6724407 www.abb.com/mediumvoltage www.abb.com/substationautomation...