4.13
M+SF_OUTC_R
Overview
Item
Description
Function name
Output control
Functional overview
Control of a safety output with a signal from the standard application and a safety signal with optional startup inhibits.
Symbol
(1)
B: i_bActivate
(2)
B: i_bS_SafeControl
(3)
B: i_bProcessControl
(4)
B: i_bStaticControl
(5)
B: i_bS_StartReset
(6)
B: i_bS_AutoReset
(7)
B: i_bReset
Labels
■ Input labels
No.
Variable name
Data type
(1)
i_bActivate
Bit
(2)
i_bS_SafeControl
Bit*
(3)
i_bProcessControl
Bit
(4)
i_bStaticControl
Bit
(5)
i_bS_StartReset
Bit*
(6)
i_bS_AutoReset
Bit*
(7)
i_bReset
Bit
■ Output labels
No.
Variable name
Data type
(8)
o_bReady
Bit
(9)
o_bS_OutControl
Bit*
(10)
o_bError
Bit
(11)
o_wDiagCode
Word [signed]
M+SF_OUTC_R
o_bReady: B
o_bS_OutControl: B
o_bError: B
o_wDiagCode: W
Default value
Description
OFF
Activation of the safety FB.
For details, see the following.
Page 11 General Functions
OFF
Safety output signals from other FB libraries.
OFF: Safety output signals from other FB libraries are OFF.
ON: Safety output signals from other FB libraries are ON.
OFF
Control signal from the standard application.
OFF: Request to set i_bS_OutControl to OFF.
ON: Request to set i_bS_OutControl to ON.
OFF
Optional conditions for process control. (Constant)
OFF: Dynamic change at i_bProcessControl (OFF to ON) required after FB activation
or triggered safety function.
ON: No dynamic change at i_bProcessControl (OFF to ON) required after FB
activation or triggered safety function. If i_bProcessControl is set to ON, safety
output is set to ON.
OFF
Selection of a reset method for the activated (first time) safety FB.
For details, see the following.
Page 11 General Functions
OFF
Selection of a reset method for the input signal reset to ON.
For details, see the following.
Page 11 General Functions
OFF
Reset input.
For details, see the following.
Page 11 General Functions
Default value
Description
OFF
Status of whether the safety FB is activated or not.
For details, see the following.
Page 11 General Functions
OFF
Controls connected actuators.
OFF: Disable connected actuators.
ON: Enable connected actuators.
OFF
Error flag.
For details, see the following.
Page 11 General Functions
0
Diagnostic code.
For details, see the following.
Page 11 General Functions
(8)
(9)
(10)
(11)
4 SAFETY FB SPECIFICATIONS
4.13 M+SF_OUTC_R
4
87