4 Connectors Pinout

4.1 Base Unit – Pinout Connectors
4.1.1 Base Unit – Remote 1 – Serial connection
Remote connection is managed through RS232 or RS-422.
For RS-232 configuration, a short-circuit must be done between Pin 4 & Ground (Pin 1 or Pin5).
Baud rate can be up to 700K baud without any specific configuration.
Pin SubD9-F - Remote RS-232
1 - (Do not used)
2 OUT : TxD
3 IN : TxD
4 RS-4xx (short-circuit to ground)
5 Ground
6 - (Not used)
7 - (Not used)
8 - (Not used)
9 - (Not used) → +12V
* Note: Differential RS-422 inputs includes 120R termination resistors
4.1.2 Base Unit – Remote 2 – Ethernet (USB on Head Unit)
Ethernet (RJ45) on Base side is used to connect a remote control or other to the
camera through a dedicated Ethernet or USB cable on Head unit side.
4.1.3 Base Unit – Remote 3 – Serial connection
Serial control can be sent through RS-232(TTL level). Baud rate can be up to 9600
baud.
Pin MiniDIN 6p-F - Remote RS232 (TTL level)
1
Ground
2
IN : RS3_RM/CTL
3
Ground
4
OUT : RS3_SID2
5
IN : RS3_SID1
6
OUT : +12V
SubD9-F - Remote RS-422(*)
1 Ground
2 OUT : RS_TX-
3 IN : RS_RX+
4 - (Not used)
5 Ground
6 OUT : RS_TX+
7 - (Not used)
8 IN : RS_RX-
9 +12V