Parameter
Weight fully loaded
(backplane, air filter, 2 fan
trays, 10 SFM3s, RPMs, and
14 line cards)
Thermal Output
Maximum (fully-loaded
chassis with 10-port 10GE
line cards)
Minimum (chassis with one
10-port 10GE line card)

E1200i ExaScale Environmental Parameters

Parameter
Operating
Temperature
Maximum altitude
Relative humidity
Shock
Vibration
Non-operating
Temperature
Maximum Altitude
Relative Humidity
Vibration

E1200i ExaScale Power Requirements

Parameter
Nominal input voltage 200-240 VAC 50/60 Hz
Maximum Power
Consumption
E1200i AC Specifications E1200i DC Specifications
422 pounds (approx.)
(191.2 kg)
18,368 BTU/hr
2,313 BTU/hr
Specifications
32° to 104°F (0° to 40°C)
No performance degradation to 10,000 feet (3,048 meters)
5 to 85 percent, non-condensing
Designed to meet Telcordia GR-63 CORE
Designed to meet Telcordia GR-63 CORE
-40° to 158°F (-40° to 70°C)
15,000 feet (4,572 meters)
5 to 95 percent, non-condensing
Bellcore GR-63
E1200i AC Specifications
6,634 W
319 pounds (approx.)
(144.70 kg)
16,446 BTU/hr
1,997 BTU/hr
E1200i DC Specifications
-44 to 60 VDC
5,400 W