Motor components
6.2 Encoder (option)
6.2.2

Encoder connection for motors with DRIVE-CLiQ

Motors with DRIVE-CLiQ have a sensor module that includes the encoder evaluation,
the motor temperature sensing and an electronic rating plate.
This sensor module instead of the signal connector and has a 10-pin RJ45-plus socket.
Warning
The sensor module contains motor and encoder-specific data as well as an electronic rating
plate. This is the reason that this sensor module may only be operated on the original motor
- and may not be mounted onto other motors or replaced by a sensor module from other
motors.
The sensor module has direct contact to components that can be destroyed by electrostatic
discharge (ESDS). Neither hands nor tools that could be electrostatically charged may come
into contact with the connections.
6.2.3

Encoder connection for motors without DRIVE-CLiQ

Motors without DRIVE-CLiQ are connected using the 17-pin flange socket.