REFRIGERANT PIPING CONNECTIONS

Directional Pipe Formation

Special Applications
If an additional drain hose is necessary, the end of drain outlet
must be routed above the ground. Secure and the drain hose
appropriately.
When the Outdoor Unit is Installed Below the Indoor Unit:
1. Use a conduit, piping set cover, or bundle the (separately) insu-
lated refrigerant piping, the drain hose, and the communications /
connection (power) cable together.
2. Make sure to include some slack in the wiring. Wiring must be
installed in an upwards direction to prevent water from entering the
control box.
3. Secure the conduit, piping set cover, or bundle along the outside
wall using saddles or a similar type of piping support.
4. Seal any openings in the wall that are around the piping.
When the Outdoor Unit is Installed Above the Indoor Unit:
1. Use a conduit, piping set cover, or bundle the (separately) insulat-
ed refrigerant piping and the communications / connection (power)
cable together up to the outdoor unit service valves.
2. Make sure to include some slack in the wiring. Wiring must be
installed in upwards direction to prevent water from traveling into the
control box.
3. If necessary, secure the conduit, piping set cover, or bundle along
the outside wall using saddles or a similar type of piping support.
4. Ensure the insulated drain hose from the indoor unit is installed
away from the outdoor unit, and in a downwards direction. If neces-
sary, secure along the outside wall using saddles or a similar type of
support.
5. Seal any openings in the wall that are around the piping.
Always include plenty of insulation on all refrigerant and drain piping to
ensure condensate does not form and cause damage to walls, floors,
etc.
38
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Figure 41: Bundling and Taping.
Bundling Piping
Drain hose
Figure 42: Special Applications.
Outdoor Unit Below Indoor Unit
Seal the small access hole
in the wall around the piping.
Outdoor Unit Above Indoor Unit
Seal the small access hole
in the wall around the piping.
Drainage from the Indoor Units
Pipe
Vinyl tape (narrow)
Wrap with
vinyl tape (wide)
Insulation
Drain Hose
Piping
Communication
Cables
Power Wiring
Drainage from the Indoor Units