Download Print this page
Mitsubishi Electric FX3U-7DM-HLD User Manual
Mitsubishi Electric FX3U-7DM-HLD User Manual

Mitsubishi Electric FX3U-7DM-HLD User Manual

Programmable controllers

Advertisement

Quick Links

JY997D15401G
Side
JAPANESE
A
Side
ENGLISH
B
FX
-7DM-HLD
3U
USER'S MANUAL
Manual Number
JY997D15401
Revision
G
Date
April 2015
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective April 2015
Specifications are subject to change without notice.
©
2004 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.
Depending on the circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
Series
JY997D16501
E x pl ai ns th e FX
Se rie s PL C
3U
3 U
User's Manual
MODEL CODE:
s p e c i f i c a t i o n s f o r I / O , w i r i n g ,
- Hardware Edition
09R516
installation, and maintenance.
FX
3UC
Series
JY997D28701
Explains the FX
3UC
Series PLC
User's Manual
MODEL CODE:
s p e c i f i c a t i o n s f o r I / O , w i r i n g ,
- Hardware Edition
09R519
installation, and maintenance.
FX
/FX
/FX
/
3S
3G
3GC
FX
/FX
Series
JY997D16601
Describes PLC programming for
3U
3UC
Programming Manual
MODEL CODE:
b a s i c / a p p l i e d i n s t ru c t i o n s a n d
- Basic & Applied
09R517
devices.
Instruction Edition
For the operation of the display module, refer to the PLC main unit manual.
→ Refer to the FX
Series User's Manual - Hardware Edition
3U
→ Refer to the FX
3UC
Series User's Manual - Hardware Edition
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
1. Outline
The FX
-7DM-HLD display module holder is the attachment (cable accessory)
3U
which installs the display module (FX
-7DM) for the FX
or FX
3U
3U
3UC
PLC to near by control panel.
Side
B
1.1 Incorporated Items
Verify that the product and accessories shown below are included in the package:
Display holder
PLC cover
Tightening bolt
Extension cable with ferrite core
(M4 × 25) × 2 pieces
[1.4m(4'7")]
Cable tie × 1 piece
1.2 External Dimensions and Part Names
Display Holder
70(2.76")
Unit:mm(inches)
53(2.09")
MASS(Weight):20g(0.05lbs)
Mounting
bracket
Display module fixing hook
59(2.33")
4(0.16")
5(0.2")
49(1.93")
may also
Guides
Guides
Panel thickness must be between
1 and 5 mm (0.04" and 0.19").
Display module fixing hook
Extension cable guiding slit
PLC Cover
48(1.89")
11.5(0.46")
Guides
Extension Cable
Display module side
(Male connector)
8.4(0.34")
1400(4'7")
250(9.84")-300(11.81")
-32MT-LT
Ferrite core [φ21.5(0.85") × 35(1.38"), 2 turns,
ZCAT2235-1030A(Manufactured by TDK co., Ltd.)]
2. Panel Cut Dimension
54
Mounting bracket
× 2 pieces
Clamp A
Clamp B
× 5 pieces
× 1 piece
In addition to the dimension above, space for mounting brackets is required by
Manual
approximately 10 mm (0.4") in the right and left directions respectively.
This
manual
3. Installation
INSTALLATION
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in this
manual.
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
2
impacts, or exposed to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• Use screwdrivers carefully when performing installation work, thus avoiding
28(1.11")
accident or product damage.
• When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
• Connect product securely to their designated connectors.
Loose connections may cause malfunctions.
• Do not pull the cable when attaching or detaching the connector.
Doing so may cause wire breakage.
3.1 Before Installation
3.1.1
FX
Series PLC
3U
1) Power off the PLC.
2) Pushing the top cover hook (fig. A),
remove the top cover (fig. B), as shown in
the right figure.
Unit:mm(inches)
MASS(Weight):
10g(0.03lbs)
3.1.2
FX
-32MT-LT PLC
3UC
1) Power off the PLC.
2) Gently place the tip of a flat head screwdriver to
the Display module fixing hooks (fig. A).
Unit:mm(inches)
3) Tilt the flat head screwdriver at the two Display
PLC side
module fixing hooks (fig. A) to lift the display
(Female connector)
module from the main unit by about 1 mm
6(0.24")
(0.04").
Carefully perform the above trying not to bend
or break the Display module fixing hooks (fig.
A).
4) Hold the display module (fig. B) and
remove the display module.
+1
+0.03"
(2.13"
)
Unit:mm(inches)
0
0
3.2 Installation to Display Holder
1) Install the display module (fig. A) to the
display holder (fig. B).
Press in until the display module surface
becomes level with the display holder
surface.
3.3 Mounting to Control Panel (Cabinet)
Mount the display module to the control panel after installing it to the display
holder.
1) Drill an mounting hole on the panel face.
, H
S, SO
, or NO
), flammable gas, vibration or
2
2
2
The panel thickness to which the display module is mounted must be between
1 and 5 mm (0.04" and 0.19").
2) Insert the display holder (fig. A)
from the front of the panel (fig. B).
B
3) Insert the tightening bolt (fig. D) into the
A
mounting bracket (fig. C).
Be careful of the direction and insert
correctly as indicated on the right.
4) Inset the hook of mounting bracket (fig.
C) into the mounting hook holes (fig. E)
on display holder (fig. A) as shown in the
right figure.
5) Slide the mounting bracket (fig. C)
upward to fix it.
2)
6) Tighten two tightening bolts (fig. D) on
3)
the right and left until the display holder
(fig. A) is securely fastened.
Tightening torque
A
B
4)
B
1)
A
→ For panel cut dimension, refer to chapter 2
Panel thickness: 1 to 5 mm
(0.04" to 0.19").
B
A
C
D
A
E
C
5)
4)
A
0.18 to 0.22 N
m
D

Advertisement

loading

Summary of Contents for Mitsubishi Electric FX3U-7DM-HLD

  • Page 1 (Male connector) (Female connector) How to obtain manuals module from the main unit by about 1 mm the right and left until the display holder For product manuals or documents, consult with the Mitsubishi Electric dealer 8.4(0.34") 1400(4’7") 6(0.24") (0.04").
  • Page 2 Cable tie This manual confers no industrial property rights or any rights of any other kind, 5) Place the right figure H side of the display nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be Frequency Acceleration Half amplitude module mounting top cover (fig.
  • Page 3 Cable tie This manual confers no industrial property rights or any rights of any other kind, 5) Place the right figure H side of the display nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be Frequency Acceleration...