Operation
VERDERAIR VA 25
Air-Operated
Diaphragm Pump
1-inch pump with modular air valve for fluid transfer applications.
For professional use only.
See page 3 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure
125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
ti13946a
VA25A
Aluminum
VA25S
Stainless Steel
ti14342a
VA25P
Polypropylene
VA25C
Conductive
Polypropylene
VA25F
PVDF
Patents Pending
End
Flange
859.0088
Rev. G
EN
Center
Flange
ti13843a
ti13844a
0359

Advertisement

Table of Contents
loading

Summary of Contents for Motorola Verizon moto g6

  • Page 1 Operation VERDERAIR VA 25 Air-Operated 859.0088 Diaphragm Pump Rev. G 1-inch pump with modular air valve for fluid transfer applications. For professional use only. See page 3 for model information, including approvals. 125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure 125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure Important Safety Instructions VA25P...
  • Page 2: Table Of Contents

    Contents Related Manuals ......2 Maintenance ......15 Pump Matrix .
  • Page 3: Pump Matrix

    Pump Matrix Check the identification plate (ID) for the 20-digit part number of your pump. Use the following matrix to define the components of your pump. For example, pump number VA25A-A01AA1SSBNBNPT represents a 1 inch, 50 gpm aluminum pump (VA25A), with aluminum center section (A01), a standard air valve (A), aluminum fluid covers (A) and manifolds with standard ports in inches (1).
  • Page 4: Atex Certifications

    ATEX Certifications ★ All ‡ VA25S (Stainless Steel) pumps VA25A (Aluminum) and with aluminum or conductive poly- VA25C (Conductive Polypropylene) propylene centers are certified: pumps are certified: II 2 GD c IIC T4 II 2 GD c IIC T4 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equip- ment.
  • Page 5 WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest •...
  • Page 6: Installation

    WARNING PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage. Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated •...
  • Page 7: Mounting

    Mounting ground. A ground wire and clamp, Part 819.0157, is available. The pump exhaust air may contain contam- • Polypropylene and PVDF: Only aluminum, inants. Ventilate to a remote area. See Air conductive polypropylene, and stainless steel Exhaust Ventilation on page 8. pumps have a ground screw.
  • Page 8: Air Line

    Check your system electrical continuity after Reed Switch the initial installation, and then set up a regular Pulse Count kits are available for use with cus- schedule for checking continuity to be sure tomer-supplied fluid management or inventory proper grounding is maintained. tracking systems.
  • Page 9: Fluid Supply Line

    Key: Air supply line Bleed-type master air valve Air regulator Air inlet Master air valve (for accessories) Air line filter Muffler Grounded air exhaust hose Container for remote air exhaust ti14219b . 2. Vent exhaust air Fluid Supply Line Fluid Outlet Line See F .
  • Page 10 ti14163a . 3. Typical bung-mount installation (aluminum, VA25A, pump shown) 859.0088...
  • Page 11 ti14164a . 4. Typical floor-mount installation (polypropylene, VA25P, pump shown) Key for F . 3 and F . 4: N Fluid outlet (Aluminum, F . 3, four ports, one not visible; Plastic, F . 4, center or end flanges available; Stainless Steel, not pictured, one port) A Air supply line R Ground wire (required for aluminum, conductive B Bleed-type master air valve (required for pump)
  • Page 12: Fluid Inlet And Outlet Ports

    Fluid Inlet and Outlet Ports Standard pipe flange kits are available in poly- propylene (819.6885), stainless steel NOTE: Remove and reverse the manifold(s) to (819.6886), and PVDF (819.6887). These kits change the orientation of inlet or outlet port(s). include: Follow Torque Instructions on page 16. the pipe flange •...
  • Page 13: Fluid Pressure Relief Valve

    Fluid Pressure Relief Valve Some systems may require installation of a Overpressurization also can occur if the pump pressure relief valve at the pump outlet to pre- is used to feed fluid to a piston pump, and the vent overpressurization and rupture of the intake valve of the piston pump does not pump or hose.
  • Page 14: Operation

    Operation Pressure Relief Procedure Starting and Adjusting the Pump 1. Be sure the pump is properly grounded. Refer to Grounding on page 7. Trapped air can cause the pump to cycle 2. Check fittings to be sure they are tight. Use unexpectedly, which could result in serious a compatible liquid thread sealant on male injury from splashing.
  • Page 15: Pump Shutdown

    9. If you are flushing, run the pump long Flushing and Storage enough to thoroughly clean the pump and hoses. 10. Close the dispensing valve, if used. Flush before fluid can dry in the equipment, • 11. Close the bleed-type master air valve. at the end of the day, before storing, and before repairing equipment.
  • Page 16: Torque Instructions

    Torque Instructions NOTE: Fluid cover and manifold fasteners have a thread-locking adhesive patch applied to the threads. If this patch is excessively worn, the fasteners may loosen during operation. Replace screws with new ones or apply medium-strength (blue) Loctite or equivalent to the threads.
  • Page 17: Dimensions And Mounting

    Dimensions and Mounting Aluminum (VA25A) ti12212b ti12211b 5.0 in. (127 mm) 5.5 in. (140 mm) ti12213b ti14540b J..3.9 in. (99 mm) A ..12.7 in. (323 mm) K ..10.2 in. (258 mm) B ..14.4 in. (366 mm) L ..
  • Page 18: Polypropylene (Va25P), Conductive Polypropylene (Va25C), And Pvdf (Va25F), Center Flange

    Polypropylene (VA25P), Conductive Polypropylene (VA25C), and PVDF (VA25F), Center Flange ti13845b ti13847b ti13846b ti14541b H..6.2 in. (1158 mm) A ..13.2 in. (335 mm) J ..3.9 in. (99 mm) B ..15.7 in. (399 mm) K..10.2 in. (258 mm) C ..
  • Page 19: Polypropylene (Va25P), Conductive Polypropylene (Va25C), And Pvdf (Va25F), End Flange

    Polypropylene (VA25P), Conductive Polypropylene (VA25C), and PVDF (VA25F), End Flange ti14820a ti14823a ti14821a ti14822 H..6.2 in. (158 mm) A..13.2 in. (335 mm) J ..3.9 in. (99 mm) B..15.7 in. (399 mm) K..10.2 in. (258 mm) C..
  • Page 20: Stainless Steel (Va25S)

    Stainless Steel (VA25S) ti14343b ti14344b ti14345b ti14345b ti14542b J ..4.0 in. (102 mm) A ..11.8 in. (300 mm) K..10.2 in. (258 mm) B ..12.9 in. (328 mm) L ..1/2 npt(f) air inlet C ..13.7 in. (348 mm) M ..
  • Page 21: Performance Charts

    Performance Charts Test Conditions: Pump tested in water with inlet submerged. Cycle Rate (0.83. 8.3) Fluid Pressure (0.7, 7.0) (0.55, 5.5) Operating Air Pressure (0.41, 4.1) 125 psi (0.83 MPa, 8.3 bar) (0.28, 2.8) 100 psi (0.7 MPa, 7.0 bar) (0.14, 1.4) 70 psi (0.48 MPa, 4.8 bar) (19)
  • Page 22: Technical Data

    Technical Data Maximum fluid working pressure ....... . . 125 psi (0.86 MPa, 8.6 bar) Air pressure operating range .
  • Page 23 Operating Temperature Range NOTICE Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid temperature range. Stay within the temperature range of the most-restricted wetted compo- nent. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.
  • Page 24 EC-DECLARATION OF CONFORMITY EG-VERKLARING VAN OVEREENSTEMMING, DÉCLARATION DE CONFORMITÉ CE, EG-KONFORMITÄTSERKLÄRUNG, DICHIARAZIONE DI CONFORMITÀ CE, EF-OVERENSSTEMMELSESERKLÆRING, ΕΚ-ΔΗΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ, DECLARAÇÃO DE CONFORMIDADE – CE, DECLARACIÓN DE CONFORMIDAD DE LA CE, EY-VAATIMUSTENMUKAISUUSVAKUUTUS, EG-DEKLARATION OM ÖVERENSSTÄMMELSE, ES PROHLÁŠENÍ O SHODĚ, EÜ VASTAVUSDEKLARATSIOON, EC MEGFElELŐSÉGI NYILATKOZAT, EK ATBILSTĪBAS DEKLARĀCIJA, ES ATITIKTIES DEKLARACIJA, DEKLARACJA ZGODNOŚCI UE, DIKJARAZZJONI-KE TA’...
  • Page 25: Customer Services/Guarantee

    Customer Services/Guarantee CUSTOMER SERVICES If you require spare parts, please contact your local distributor, providing the following details: Pump Model • Type • Serial Number, and • Date of First Order. • GUARANTEE All VERDER pumps are warranted to the original user against defects in workmanship or materials under normal use (rental use excluded) for two years after purchase date.
  • Page 26 Austria Belgium China Verder Austria Verder nv Verder Retsch Shanghai Trading Eitnergasse 21/Top 8 Kontichsesteenweg 17 Room 301, Tower 1 A-1230 Wien B–2630 Aartselaar Fuhai Commercial Garden no 289 AUSTRIA BELGIUM Bisheng Road, Zhangjiang Tel: +43 1 86 51 074 0 Tel: +32 3 877 11 12 Shanghai 201204 Fax: +43 1 86 51 076...

Table of Contents