Sony HCD-D11 Service Manual page 3

Tuner cd player
Table of Contents

Advertisement

QQ
3 7 63 1515 0
SAFETY CHECK-OUT
After correcting the original service problem, perform the fol-
lowing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers.). Leak-
age current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The "limit" indication is 0.75
V, so analog meters must have an accurate low-voltage scale.
The Simpson 250 and Sanwa SH-63Trd are examples of a pas-
sive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2 V AC range are suitable. (See Fig. A)
TE
L 13942296513
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
www
.
http://www.xiaoyu163.com
To Exposed Metal
Parts on Set
1.5 k Ω
Earth Ground
x
ao
y
i
http://www.xiaoyu163.com
8
Laser component in this product is capable of emitting radiation
exceding the limit for Class 1.
CAUTION
Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
SAFETY-RELATED COMPONENT WARNING!!
Q Q
3
COMPONENTS IDENTIFIED BY MARK ! OR DOTTED
6 7
1 3
LINE WITH MARK ! ON THE SCHEMATIC DIAGRAMS
AND IN THE PARTS LIST ARE CRITICAL TO SAFE
OPERATION. REPLACE THESE COMPONENTS WITH
SONY PARTS WHOSE PART NUMBERS APPEAR AS
AC
voltmeter
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB-
(0.75 V)
LISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE !
SUR LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE
DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ
DE FONCTIONNEMENT. NE REMPLACER CES COM-
POSANTS QUE PAR DES PIÈCES SONY DONT LES
NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
u163
.
– 3 –
2 9
9 4
2 8
This appliance is classified as a
CLASS 1 LASER product.
The CLASS 1 LASER PROD-
UCT MARKING is located on the
rear exterior.
1 5
0 5
8
2 9
9 4
À LA SÉCURITÉ!
m
co
9 9
This caution label
is located inside
the unit.
2 8
9 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcd-t11