Download Print this page

Kenwood TS-890S Command Reference Manual page 38

Pc control command
Hide thumbs Also See for TS-890S:

Advertisement

IS
Receive Filter Shift Frequency
1
2
3
Set
I
S
P1
1
2
3
Read
I
S
;
1
2
3
Answer
I
S
P1
KS
Keying Speed
1
2
3
Set
K
S
P1
1
2
3
Read
K
S
;
1
2
3
Answer
K
S
P1
KY
CW Keying
1
2
3
Set 1
K
Y
P1
1
2
3
Set 2
K
Y
P1
1
2
3
Read
K
Y
;
1
2
3
Answer
K
Y
P1
PC Control Command referenCe guide
4
5
6
7
8
P2
P2
P2
P2
;
4
5
6
7
8
4
5
6
7
8
P2
P2
P2
P2
;
4
5
6
7
8
P1
P1
;
4
5
6
7
8
4
5
6
7
8
P1
P1
;
4 ~
x
P2
;
4
5
6
7
8
;
4
5
6
7
8
4
5
6
7
8
;
Parameters:
P1
9
10
+: Plus direction
–: Minus direction
 If the shift frequency is 0 Hz, You can use either +, –, and
9
10
space.
P2
Shift Frequency (4 digits in Hz)
9
10
 For the settable shift frequency, refer to the table below.
If other shift frequency is specified, it is corrected to the
settable shift frequency.
 Entering a value of 9999 results in the initial value being
entered. (P1 can be use either +, –, and space)
Shift frequency range for SSB (Hz)
50~2500
Parameters:
P1
9
10
004 ~ 060
9
10
9
10
Parameters:
P1 (Keying string buffer state)
For Setting 1, always enter a space or "2".
For Setting 2, entering 0 will cause Setting 1 to stop. An error
will occur if any value other than 0 is entered.
9
10
In response command, outputs the following value.
0: Character buffer space
1: No character buffer space
9
10
P2 (Enter a character string for keying (1 to 24 characters))
The characters listed in the following table can be entered.
9
10
A
B
C
K
L
M
U
V
W
a
b
c
k
l
m
u
v
w
0
1
2
(space)
'
.
/
:
Using abbreviations, you can enter the following symbols:
Abbreviation
BT
AR
AS
HH
• When setting spaces in parameter P1, the parameter P2 has
a fixed length of 24 bytes. Characters that are left blank will
be filled with spaces, but these spaces will not be converted to
morse code. Continuously set spaces are keying as a single
space.
• When setting "2" in parameter P1, the parameter P2 has a
maximum variable length of 24 bytes. Continuously set spaces
are keying as continuous spaces.
• Although you can use lower-case letters as well as upper-
case letters for the P2 parameter, there is no distinction made
between them when sending the morse code.
• You cannot enter a semicolon (;) for the P2 parameter.
– 37 –
Shift frequency range for CW (Hz)
50 STEP
–800~800
D
E
F
G
H
N
O
P
Q
R
X
Y
Z
d
e
f
g
h
n
o
p
q
r
x
y
z
3
4
5
6
7
"
(
)
*
+
=
?
@
Symbol
Abbreviation
[
SK
_
KN
<
BK
#
SN
10 STEP
I
J
S
T
i
j
s
t
8
9
,
Symbol
>
]
\
%

Advertisement

loading