Fujitsu ETERNUS DX60 S3 Operation Manual
Fujitsu ETERNUS DX60 S3 Operation Manual

Fujitsu ETERNUS DX60 S3 Operation Manual

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

P3AM-9012-08ENZ0
FUJITSU Storage
ETERNUS DX60 S4,
ETERNUS DX60 S3
Hybrid Storage Systems
Operation Guide (Basic)
Operation management/maintenance

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ETERNUS DX60 S3

  • Page 1 P3AM-9012-08ENZ0 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Operation management/maintenance...
  • Page 2: Table Of Contents

    Displaying Status via ETERNUS Web GUI ..................43 Displaying Status via ETERNUS CLI ....................44 Event Notification ......................... 44 Audit Log ............................45 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 3 Maintenance Service........................76 Maintenance Support Period..........................76 Replacing Batteries ...............................76 Related Service..............................77 6. Troubleshooting Check List............................78 Required Information for Inquiries....................86 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 4 OFF Position (Marked "¡") of the PSU Switch of a Power Supply Unit ............37 Figure 40 ETERNUS Web GUI Screen .........................43 Figure 41 Event Notification ............................45 Figure 42 Audit Log..............................46 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 5 Status and Meanings of Each LED (Power Supply Unit (Drive Enclosure)) ..........28 Table 11 General Status of ETERNUS Web GUI......................43 Table 12 General Status of ETERNUS CLI .........................44 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 6 Preface Fujitsu would like to thank you for purchasing the FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 (herein- after referred to as ETERNUS DX). The ETERNUS DX is designed to be connected to Fujitsu servers (Fujitsu SPARC Servers, PRIMEQUEST, or PRIMER- GY) or non-Fujitsu servers.
  • Page 7 Indicates information that you need to observe when using the ETERNUS storage system. Make sure to read the information. Indicates information and suggestions that supplement the descriptions included in this manual. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 8 - Do not use alcohol or other solvents to clean the ETERNUS storage system. Warning layout ribbon FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 9: Component Names And Led Names

    An operation panel and drives are installed in the front of the controller enclosure. Controllers and power supply units are installed in the rear. Note that some LED names of the controllers are different in the ETERNUS DX60 S4 and the ETERNUS DX60 S3. Front This section provides the names of the components on the front of a controller enclosure.
  • Page 10: Rear

    Figure 4 Rear View of a Controller Enclosure (When Two Controllers Are Installed) Controller (CM#0) Controller (CM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 11: Components (Front)

    The installation location of the controller enclosure is identified (blinks blue) according to the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 12 There is data in the cache memory of the ETERNUS DX. (green) READY The ETERNUS DX is available for use. (green) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 13: Figure 6 2.5" Drives

    Figure 9 Drive Slot Numbers (3.5" Type Controller Enclosure) Slot#8 Slot#9 Slot#10 Slot#11 Slot#4 Slot#5 Slot#6 Slot#7 Slot#0 Slot#1 Slot#2 Slot#3 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 14: Eternus Dx60 S4 Components (Rear)

    10Gbit/s SAS 6Gbit/s SAS 12Gbit/s PWC port This port is used to connect a power synchronization unit with an RS232C cable. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 15 17. LAN LINK LED 18. READY/FAULT LED 19. LINK/FAULT LED 20. FAULT LED 21. LINK LED 22. CA#0 FAULT LED 23. MASTER LED FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 16: Table 3 Status And Meanings Of Each Led (Controller)

    (amber) CA FAULT The host interface is in error status. (amber) MASTER The controller is set as a Master CM. (green) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 17: Eternus Dx60 S3 Components (Rear)

    The controller contains a CPU, cache memory, System Capacitor Unit (SCU), host interfaces, drive interface (DI) ports, and LAN ports. The controller controls all operations in the ETERNUS DX. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 18: Figure 12 Controllers

    Host interface port (iSCSI port) (CA#0, Port#1) This port is used for connecting a LAN cable. This port uses an RJ-45 connector. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 19: Table 5 Status And Meanings Of Each Led (Controller)

    The link between the host interface port (FC or SAS) and the des- (green) tination port has been established. The host interface port (FC or SAS) is in error status. (amber) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 20 (amber) CA FAULT The host interface is in error status. (amber) MASTER The controller is set as a Master CM. (green) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 21: Figure 13 Power Supply Unit (Controller Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 22: Drive Enclosures

    Flange cover ■ 3.5" Type Figure 15 Front View of a 3.5" Type Drive Enclosure Operation panel 3.5" drive Flange cover FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 23: Rear

    Figure 17 Rear View of a Drive Enclosure (When Two I/O Modules Are Installed) I/O module (IOM#0) I/O module (IOM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 24: Components (Front)

    ETERNUS CLI. FAULT The drive enclosure is in error status. (amber) POWER DC power is supplied to the drive enclosure. (green) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 25: Figure 19 2.5" Drives

    Figure 22 Drive Slot Numbers (3.5" Type Drive Enclosure) Slot#8 Slot#9 Slot#10 Slot#11 Slot#4 Slot#5 Slot#6 Slot#7 Slot#0 Slot#1 Slot#2 Slot#3 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 26: Components (Rear)

    LED status Meaning DI (IN) LINK The link between the DI (IN) port and the source port has been (green) established. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 27 ETERNUS Web GUI or ETER- NUS CLI. FAULT The I/O module is in error status. (amber) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 28: Figure 24 Power Supply Unit (Drive Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 29: Power Distribution Units (For Regions Other Than The Emeia, Central American, And Caribbean Re- Gions)

    This is a socket (IEC60320 C14) for incoming power supply. This socket is used to connect a power cord (AC input cable). FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 30: Power Distribution Units (2U)

    Figure 28 Power Distribution Unit (AC200-240V, 2U, 16 Outlets) Main line switch This turns on and off the power distribution unit. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 31: Figure 29 Power Distribution Unit (Ac200-240V, 2U, 16 Outlets)

    This is a socket (IEC60320 C13) for outgoing power supply. This socket is used to connect a power cord (AC out- put cable). FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 32: Basic Operation

    Main line switch Figure 31 ON Position of the Main Line Switches on a 1U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 33: Figure 32 On Position (Marked "|") Of The Main Line Switches On A 2U Power Distribution Unit

    39), turn all the PSU switches of the power supply unit to the OFF posi- tion, and turn the main line switch to the OFF position. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 34: Figure 34 Off Position (Marked "¡") Of The Main Line Switches On A 1U Power Distribution Unit

    Main line switch Figure 35 OFF Position of the Main Line Switches on a 1U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 35: Figure 36 Off Position (Marked "¡") Of The Main Line Switches On A 2U Power Distribution Unit

    When turning the main line switch to ON (marked "|") right after turning the main line switch to OFF (marked "¡"), turn it back to ON (marked "|") after the POWER LED of the power supply unit has turned off completely. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 36: Switching On And Off The Psu Switch On The Power Supply Unit

    For the drive enclosure, the POWER LED on the power supply unit emits green lights and the fan revolves at • high speed for 30 seconds. Drive enclosure Controller enclosure Power supply unit (PSU#0) Power supply unit (PSU#1) POWER FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 37: Figure 39 Off Position (Marked "¡") Of The Psu Switch Of A Power Supply Unit

    Figure 39 OFF Position (Marked "¡") of the PSU Switch of a Power Supply Unit Power supply unit (PSU#0) Power supply unit (PSU#1) Check that the POWER LED of the power supply unit is off. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 38: Powering On

    This section explains how to use the Power switch to turn on the ETERNUS DX. For other procedures, refer to the related manuals. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 39: Powering Off

    The following methods can be used to turn off the power by linking with the server. • Via the power synchronized unit Use the power synchronized unit to turn off the ETERNUS DX. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 40 LED turning off and the POWER LED turning off, the ETERNUS DX power may turn on. The power of the ETERNUS DX is disconnected. When the power is disconnected, the POWER LED is turned off. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 41: Using The Function Button

    Use the pin to push down the FUNCTION button for three seconds. The ETERNUS DX is in maintenance status when the MAINTENANCE LED is green. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 42 The MAINTENANCE LED turns off, which indicates that the ETERNUS DX is no longer in maintenance status. Attach the flange cover. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 43: Storage System Monitoring

    The ETERNUS DX is in a normal state. (green) An abnormality is detected at a power-off, and I/O access from the server cannot be received. (red) FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 44: Displaying Status Via Eternus Cli

    The methods that can be used to notify an event are "e-mail", "SNMP Trap", "Syslog", "remote support", and "host sense". For the procedure on setting event notification, refer to "Configuration Guide (Basic)". FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 45: Audit Log

    ETERNUS DX and the system actions that are associated with these operations can be sent to the Sy- slog server. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 46: Figure 42 Audit Log

    User/role ↓ Process time Setting change ↓ Process details Process result Logout etc. Audit log System administrator Syslog server ETERNUS DX FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 47: Component Expansion/Function Enhancement

    To avoid this, allow the packed drive sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 48: Additional Drive Installation Procedure

    Additional Drive Installation Procedure This section explains how to install optional drives in the ETERNUS DX. Drives can be installed in any slots. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 49 Do Not Do not install drives that are for use in other devices. • FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 50 Keep the removed dummy drive units in a safe place where they will not be lost. Install the new drive. Press the catch on the drive lock lever to unlock it. Catch Lock lever FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 51 In the [Drives] screen of [Component] on the ETERNUS Web GUI screen, check that the added drives have been recognized. Set up RAID groups, volumes, hot spares, and host affinity settings, as required. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 52 Insert the drive all the way into the slot, making sure that it is firmly seated and that the lock lever is still left open. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 53 In the [Drives] screen of [Component] on the ETERNUS Web GUI screen, check that the added drives have been recognized. Set up RAID groups, volumes, hot spares, and host affinity settings, as required. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 54: Installing Additional Drive Enclosures

    To avoid this, allow the packed drive enclosure sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 55 Do not stack the drive enclosures. • Do not knock or drop the drive enclosure on hard objects. • FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 56: Additional Drive Enclosure Installation Procedure

    To disconnect the mini SAS HD cables between enclosures, hold the tab and then pull out the connector. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 57 Display the [Add Drive Enclosure] screen. In the [Storage] screen of [Component], click [Add Drive Enclosure] in [Action]. The [Add Drive Enclosure] screen appears. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 58 Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 59 M5 screw Rack rail (right) The M5 screw positions for the rack rails are determined by the drive enclosure base line. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 60 Failure to do so may cause injury. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 61 Right front side of the drive enclosure Upper right rear side of the drive enclosure DE_No. label The DE_No. labels are supplied with the ETERNUS DX. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 62 2 is added. Drive enclosure 2 Connect here (drive enclosure that is to be added) Connect here Drive enclosure 1 FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 63 Connect the other end of the power cord plug to a power socket or an inlet on the power distribution unit. Move the PSU switches for PSU#0 and PSU#1 in the drive enclosures to the ON position (marked "|"). FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 64 When the configuration process is complete, the [Disable IOM#1] screen appears. In the IOM#1 disconnection screen, click the [Next>>] button. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 65 The following figure shows the cable (between CE and DE) that needs to be disconnected from the enclo- sures when drive enclosure 2 is added. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 66 The following figure shows how a mini SAS HD cable between enclosures (CE and DE) is connected when drive enclosure 2 is added. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 67 The following figure shows how a mini SAS HD cable between enclosures (DE and DE) is connected when drive enclosure 2 is added. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 68 For details on drive installation, refer to "Additional Drive Installation Procedure" (page 48). If a wrist strap is used, remove the wrist strap. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 69: Adding Servers

    The RAID group is registered and the registration completion screen appears. Click the [Done] button. The screen returns to the [RAID Group] screen. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 70: Volume Creation

    The volume is created and the registration completion screen appears. Click the [Done] button. The screen returns to the [Volumes] screen. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 71: Connection Setup

    Register a host in a host group, and then click the [Add] button. A confirmation screen appears. Click the [OK] button. The host group is added and the registration completion screen appears. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 72 The CA port group is created and the setting completion screen appears. Click the [Done] button. The screen returns to the [CA Port Group] screen. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 73 The LUN group is added and the setting completion screen appears. Click the [Done] button. The screen returns to the [LUN Group] screen. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 74 [Create] button. A confirmation screen appears. Click the [OK] button. The host affinity is created and the registration completion screen appears. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 75 Component Expansion/Function Enhancement Adding Servers Click the [Done] button. The screen returns to the [Connectivity] screen. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 76: Maintenance

    If a battery is used at an average temperature of 25 °C, the battery can be used for the entire maintenance sup- port period (five years). The replacement cycle for a battery varies according to the customer's environment and usage. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 77: Related Service

    If a possible error that may occur is detected or an error occurs when remote support service is used, the con- tents of events are automatically sent to the remote support center and notified to the user. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 78: Troubleshooting

    Has there been a recent main power failure? • If the Power Resume function is enabled, the ETERNUS DX turns on automatically after the power is restored. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 79 Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX. Drive enclosures with no mini SAS HD cable between enclosures connected will remain on. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 80 Protection (Shield) function works and how to check whether it is running, refer to "Design Guide (Basic)". If the problem persists, contact your maintenance engineer. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 81 Note that the settings (network environment settings and firewall settings) for all of the LAN ports are initial- ized after the following procedure is performed. Remove the flange cover of the controller enclosure. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 82 DX does not respond to SNMP access. Check whether each service can connect to the ETERNUS DX. If it cannot connect, contact your maintenance engineer. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 83 Force Prefetch mode enabled. Enable the Force Prefetch mode and specify the appropri- ate value for the Prefetch Limit. This may be caused by accesses that are used for video distribution businesses. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 84 When a switch is used, the WWN zoning settings need to be changed. For details on this setting, refer to relevant manuals of the switch. After completing the settings, confirm that access from the server is available. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 85 Set the SAS address, host affinity, and other settings of the new SAS card by referring to the information recorded in Step After completing the settings, confirm that access from the server is available. FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED P3AM-9012-08ENZ0...
  • Page 86: Required Information For Inquiries

    ETERNUS Web GUI. For details on obtaining the log/dump information, refer to "ETERNUS Web GUI User's Guide". FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic) Copyright 2018 FUJITSU LIMITED...
  • Page 87 However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information •...