Table of Contents
loading

Summary of Contents for ABB TEIP11

  • Page 1 Operating Instruction 42/18-46-EN Rev. L TEIP11, TEIP11-PS I/P signal converter...
  • Page 2 Short product description I/P signal converter for controlling pneumatic actuators or pneumatic positioners for positioning valves. Further information Additional documentation on TEIP11, TEIP11-PS is available for download free of charge at www.abb.com/positioners. Alternatively simply scan this code: Manufacturer ABB Automation Products GmbH Measurement &...
  • Page 3: Table Of Contents

    Scope of delivery ..........9     4.2.1 Accessories ............9     Transport and storage ............ 9     Inspection ............9     Storage conditions ..........9     Returning devices ..........9 TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 3...
  • Page 4: Safety

    Safety Intended use I/P signal converters for standard signals TEIP11 and TEIP11- Change from one to two columns PS are used to control pneumatic actuators or pneumatic General information and instructions positioners for positioning valves. These instructions are an important part of the product and must be retained for future reference.
  • Page 5: Use In Potentially Explosive Atmospheres

    60 °C or below -20 °C, use cable entries and cables Special Requirements suited to an operating temperature that corresponds to the The I/P converter TEIP11-PS Doc. type 901069 or Doc. maximum ambient temperature plus 10 K or that corresponds 901069-SMD must be set up outdoors as a pneumatic power to the minimum ambient temperature.
  • Page 6: Fm/Csa

    "intrinsically safe (Ex ia)" type of protection, as the electronics may have been damaged. For this reason the devices must be permanently marked during commissioning (e.g. cross out or mask over "Ex ia"). 6 42/18-46-EN Rev. L | TEIP11, TEIP11-PS...
  • Page 7: Function And System Design

    Principle of operation 3.1.1 Special features Special features of the TEIP11, TEIP11-PS I/P signal converter are its relatively small dimensions and outstanding operational stability when subject to shock and vibration. The stability is 0 … 20 / 4 … 20 mA...
  • Page 8: Designs

    A mounting base that is compatible with all commercially available EN rails is used for installation. The housing unit with plastic cap has an IP 20 protection class. 8 42/18-46-EN Rev. L | TEIP11, TEIP11-PS...
  • Page 9: Product Identification

    — For wall mounting only. — Universal for wall or 2" pipe mounting. — Cable entry for I/P signal converter with the "flameproof (enclosure) (Ex d)" type of protection. TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 9...
  • Page 10: Installation

    Mounting the unit. NOTICE Installation location requirements Prior to installation, check to ensure that the TEIP11 and TEIP11-PS I/P signal converters meet the measurement and safety requirements applicable at the installation location (see section "Additional documents" on page 14). 6.1.1 Control room housing unit for rail mounting This model is snap-mounted on a DIN top-hat rail.
  • Page 11: Aluminum/Stainless Steel Field Mount Housing

    A stainless steel mounting bracket is available as an accessory for installation. The mounting bracket is available in two designs: — For wall mounting only. — Universal for wall or 2" pipe mounting. TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 11...
  • Page 12: Electrical Connections

    4 bar (60 psi). This could result in mechanical damage to the unit. NOTICE — The TEIP11 and TEIP11-PS I/P signal converters may only be operated with instrument air that is free of oil, water, and dust.
  • Page 13: Pneumatic Data Teip11

    0,4 ... 2 bar (6 ... 30 psi) Only valid for option 509 - increased input signal Air consumption  0.2 kg/h = 0.16 Nm /h = 0.1 scfm Fig. 9: Adjustment screws 1 Span 2 Zero point TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 13...
  • Page 14: Repair

    — This product is not subject to WEEE Directive 2012/19/EU All devices delivered to ABB must be free from any hazardous or relevant national laws (e.g. ElektroG in Germany). materials (acids, alkalis, solvents, etc.).
  • Page 15: Appendix

    Which substances have come into contact with the device? We hereby state that the devices / components shipped have been cleaned and are free from any dangerous or poisonous substances. Town/city, date Signature and company stamp TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 15...
  • Page 16: Control Document

    12.1 Control Document 12.1.1 Connection diagram 900842 FM 16 42/18-46-EN Rev. L | TEIP11, TEIP11-PS...
  • Page 17 TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 17...
  • Page 18: Connection Diagram 900842 Csa

    12.1.2 Connection diagram 900842 CSA 18 42/18-46-EN Rev. L | TEIP11, TEIP11-PS...
  • Page 19 TEIP11, TEIP11-PS | 42/18-46-EN Rev. L 19...