10-29-05 : SIP Server Information Setup – Registrar Mode
Set the Registrar Mode to 1(manual) with SIP trunking.
10-29-06 : SIP Server Information Setup – Registrar IP Address
Input the IP Address of the SIP registrar (if given).
10-29-08 : SIP Server Information Setup – DNS Mode
Set the DNS Mode to 1, when the SIP carrier provides a domain name.
10-29-09 : SIP Server Information Setup – DNS IP Address
This information should be provided by your SIP service provider.
The DNS IP Address should be any valid Domain Name Server either SIP provided or within
your network.
10-29-11 : SIP Server Information Setup – Registrar Domain Name
Define the Registrar Domain Name. This information should be provided by your
SIP service provider (128 characters maximum).
10-29-12 : SIP Server Information Setup – Proxy Domain Name
Enter the domain.
When configuring Domain name the SIP service provide will supply the Proxy/Domain in the
following manner - "Host Name" . "Domain Name" . The characters are normally separated
by "." The characters after "." will be in the Domain Name.
10-29-13 : SIP Server Information Setup – Proxy Host Name
Enter the host name.
When configuring Domain name the SIP service provide will supply the Proxy/Domain in the
following manner - "Host Name" . "Domain Name" . The characters are normally separated
by "." The characters before "." will be in the Host Name.
10-29-14 : SIP Server Information Setup – SIP Carrier Choice
Set the SIP Carrier Choice to 3 (Carrier C).
Changing this program automatically changes program 10-29-16 to "on". 10-29-16 must
be turned off in order for incoming calls to route correctly.
10-29-15 : SIP Server Information Setup – Registration Expiry Time
It is important to leave this automatic re-registration time to be 3600 seconds so
that the Windstream network does not get flooded.
10-29-16 : SIP Server Information Setup – Register Sub Mode
Unchecking the Register Sub Mode (setting it to "off") will allow all trunk calls to be
routed based on routing policies.
SIP Trunking Service Configuration Guide