Siemens Simatic S7-1500 Function Manual page 36

Cycle and response times
Hide thumbs Also See for Simatic S7-1500:
Table of Contents

Advertisement

1510SP(F)-1 PN
Programming
90 μs
error
I/O access error
90 μs
Time error
90 μs
Diagnostic inter-
90 μs
rupt
Module fail-
90 μs
ure/recovery
Station fail-
90 μs
ure/recovery
CPU
Programming error
I/O access error
Time error
Diagnostic interrupt
Module failure/recovery
Station failure/recovery
Reference
You can find additional information on the topic of error handling in the Events and OBs
section of the
● S7-1500 automation system
(http://support.automation.siemens.com/WW/view/en/59191792) system manual
● S7-1500R/H redundant system
(https://support.industry.siemens.com/cs/ww/en/view/109754833) system manual
● ET 200SP distributed I/O system
(http://support.automation.siemens.com/WW/view/en/58649293) system manual
● CPU 1516pro-2 PN operating instructions
(https://support.industry.siemens.com/cs/ww/en/view/109482416)
You can find additional information on the topic of the complete cycle time of a program in an
FAQ on the Internet (https://support.industry.siemens.com/cs/ww/en/view/87668055).
Cycle and response times
Function Manual, 10/2018, A5E03461504-AD
ET 200SP
1512SP(F)-1 PN
90 μs
90 μs
90 μs
90 μs
90 μs
90 μs
1516pro(F)-2 PN
80 μs
80 μs
80 μs
80 μs
80 μs
80 μs
Cyclic program execution
1515SP(F)-PC
80 μs
80 μs
80 μs
80 μs
80 μs
80 μs
ET 200pro
3.2 Cycle time